Image Quality of Virtual Monochromatic Reconstructions of Noncontrast CT on a Dual-Source CT Scanner in Adult Patients

نویسندگان

چکیده

Rationale and ObjectivesTo evaluate the image quality of virtual monochromatic images (VMI) reconstructed from dual-energy dual-source noncontrast head CT with different reconstruction kernels.Materials MethodsTwenty-five consecutive adult patients underwent CT. VMI were retrospectively at 5-keV increments 40 to 140 keV using quantitative kernels. CT-number, noise levels (SD), signal-to-noise ratio (SNR), contrast-to-noise (CNR) in gray white matter artifacts posterior fossa artifact index (PFAI) evaluated.ResultsCT-number increased decreasing energy levels, SD was lowest 85 keV. SNR maximized 80 for kernels, respectively. CNR maximum keV; PFAI 90 (head kernel) 100 (quantitative Optimal significantly better than conventional CT.ConclusionOptimal energies can improve brain parenchymal compared but are kernel dependent depend on indication performing To Twenty-five evaluated. CT-number

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prospective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose

Background: Prospectively electrocardiography (ECG)-triggered high-pitch spiral coronary computed tomography angiography (CCTA) is a unique scan mode for dual-source CT (DSCT). Our reports aim to compare image quality and radiation dose of CCTA using high-pitch spiral or sequential acquisition mode in patients with low and stable heart rates. Materials and Methods: Patients with low and stable ...

متن کامل

Improving Image Quality of Bronchial Arteries with Virtual Monochromatic Spectral CT Images

OBJECTIVE To evaluate the clinical value of using monochromatic images in spectral CT pulmonary angiography to improve image quality of bronchial arteries. METHODS We retrospectively analyzed the chest CT images of 38 patients who underwent contrast-enhanced spectral CT. These images included a set of 140kVp polychromatic images and the default 70keV monochromatic images. Using the standard G...

متن کامل

CT venography after knee replacement surgery: comparison of dual-energy CT-based monochromatic imaging and single-energy metal artifact reduction techniques on a 320-row CT scanner

BACKGROUND An optimal metal artifact reduction (MAR) technique is needed for a reliable and accurate image-based diagnosis. PURPOSE Using a 320-row scanner, we compared the dual-energy computed tomography (CT)-based monochromatic and the single-energy metal artifact reduction (SEMAR) techniques for CT venography (CTV) to identify the better imaging method for diagnosing deep vein thrombosis (...

متن کامل

[Coronary CT angiography using a prospective protocol. Comparison of image quality and radiation dose between dual source CT and single source CT].

OBJECTIVE To compare the image quality and radiation dose in a group of patients undergoing coronary CT angiography using a 128-slice dual source helical CT scanner with high pitch alto and prospective acquisition with those in a group of patients with similar clinical characteristics undergoing coronary CT angiography using a 128-slice single-source CT scanner with prospective sequential acqui...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Academic Radiology

سال: 2021

ISSN: ['1076-6332', '1878-4046']

DOI: https://doi.org/10.1016/j.acra.2020.05.038