IEC 61850-Based Protection Scheme for Multiple Feeder Faults and Hardware-in-the-Loop Platform for Interoperability Testing
نویسندگان
چکیده
The existing Overcurrent Protection Function (OCPF) of distribution systems is vulnerable to Multiple Feeder Faults (MFF), which involve at least two feeders simultaneously, leading the incoming feeder relay trip faster than faulted relays, although OCPF relays can be coordinated for all fault current values. In this case, connected power transformer are de-energized, even healthy ones, directly impacting network reliability, service quality and availability electricity utilities ultimately outage costs customers. light this, an IEC 61850-based scheme with directional element proposed support deal MFF encompass integration distributed generation, implemented in digital substations without requiring further equipment installation. Moreover, hardware-in-the-loop platform developed testing interoperability multi-vendor protection assist also validation their control schemes based on requirements before field implementation. Test cases specifically elaborated study three real devices—whose configuration details provided aid engineers—in a system, under different conditions such as switching operations, types, resistance location, generation. results show that manages enhance selectivity reliability substation hence representing valuable complement schemes.
منابع مشابه
the search for the self in becketts theatre: waiting for godot and endgame
this thesis is based upon the works of samuel beckett. one of the greatest writers of contemporary literature. here, i have tried to focus on one of the main themes in becketts works: the search for the real "me" or the real self, which is not only a problem to be solved for beckett man but also for each of us. i have tried to show becketts techniques in approaching this unattainable goal, base...
15 صفحه اولA Close-Loop Conformance Testing System of IEC 61850
—With the development of intelligent substation in China, it becoming more important that the conformance testing of IEC 61850 is used to guarantee the interoperability between intelligent electric devices. In view of the current intelligent substation IEC 61850 conformance testing did not form a closed loop, which led to the lacking of comprehensiveness and integrity, a closed-loop conformanc...
متن کاملHardware-in-the-Loop Testing Platform for Distributed Generation Systems
Rapid validation of the expected performance of distributed generation installations is a critical step in the design process. However, the plethora of distributed generator types and the uniqueness of the load characteristics make the testing quite challenging.. This paper introduces an original approach to hardware-in-the-loop simulation aimed to evaluate the performance and suitability of di...
متن کاملReal Time Simulation Testing Using IEC 61850
-As IEC 61850 becomes more widely accepted in the electrical engineering community, it is important that the testing tools keep pace with this development. IEC 61850 presents new challenges to real time simulation and closed-loop testing of protective relays. Electrical interfaces used for binary signaling and voltage/current amplifiers must be replaced by an Ethernet connection and an IEC 6185...
متن کاملdeveloping a pattern based on speech acts and language functions for developing materials for the course “ the study of islamic texts translation”
هدف پژوهش حاضر ارائه ی الگویی بر اساس کنش گفتار و کارکرد زبان برای تدوین مطالب درس "بررسی آثار ترجمه شده ی اسلامی" می باشد. در الگوی جدید، جهت تدوین مطالب بهتر و جذاب تر، بر خلاف کتاب-های موجود، از مدل های سطوح گفتارِ آستین (1962)، گروه بندی عملکردهای گفتارِ سرل (1976) و کارکرد زبانیِ هالیدی (1978) بهره جسته شده است. برای این منظور، 57 آیه ی شریفه، به صورت تصادفی از بخش-های مختلف قرآن انتخاب گردید...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Access
سال: 2023
ISSN: ['2169-3536']
DOI: https://doi.org/10.1109/access.2023.3280128