Hybrid noise control in a duct using a light micro-perforated plate
نویسندگان
چکیده
منابع مشابه
Hybrid noise control in a duct using a light micro-perforated plate.
A plate silencer consists of an expansion chamber with two side-branch cavities covered by light but extremely stiff plates. It works effectively with a wide stopband from low-to-medium frequencies only if the plate is extremely stiff, to ensure a strong reflection of acoustic wave to the upstream in the duct. However, a plate with a slightly weak bending stiffness will result in non-uniform tr...
متن کاملPerformance of multiple micro-perforated panels in a duct
Generalized formulation is developed analytically to calculate the transmission loss performance of a silencer by using multiple micro-perforate panel (MPP) array silencers in ventilation duct system. The device, based on single MPP design, consists of different expansion chambers with the side-branch cavities covered by micro-perforate panels of different properties. The theoretical model can ...
متن کاملSound attenuation using duct silencers with micro-perforated panel absorbers
Micro-perforated panel (MPP) can be used as non-fibrous acoustic absorber which can provide broadband sound absorption performance. In this study, a sub-structuring methodology based on the Patch Transfer Function (PTF) approach to deal with duct silencers with MPP absorbers and internal partitions is proposed, and the sound attenuation performance of such silencers is investigated. Reactive si...
متن کاملActive noise control of a duct using robust control theory
In this paper, the control of sound propagation in an air-handling duct is investigated. Employing identified discrete t ime models of the duct, robust linear controllers are designed using the combined pole placement/sensitivity function shaping method. T h e particularities of harmonic noise sources are taken into account, avoiding the classical stochastic adaptive and the reference noise bas...
متن کاملActive noise control of an acoustic duct using feedback control
Forced air cooling systems, such as an airconditioning system produce noise. For a pleasant living environment, this noise is undesirable. A way to suppress produced noise is reducing the sound in the duct where the air flows through afterwards. a his report handles the noise reduction in an active duct silencer by the use of a discrete feedback controller. Models of the involved processes are ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of the Acoustical Society of America
سال: 2012
ISSN: 0001-4966
DOI: 10.1121/1.4763550