Hybrid high-energy high-power pulsewidth-tunable picosecond source
نویسندگان
چکیده
منابع مشابه
High-power picosecond fiber source for coherent Raman microscopy.
We report a high-power picosecond fiber pump laser system for coherent Raman microscopy (CRM). The fiber laser system generates 3.5 ps pulses with 6 W average power at 1030 nm. Frequency doubling yields more than 2 W of green light, which can be used to pump an optical parametric oscillator to produce the pump and the Stokes beams for CRM. Detailed performance data on the laser and the various ...
متن کاملemittance control in high power linacs
چکیده این پایان نامه به بررسی اثر سیم پیچ مغناطیسی و کاوه یِ خوشه گر با بسامد رادیویی بر هاله و بیرونگراییِ باریکه هایِ پیوسته و خوشه ایِ ذرات باردار در شتابدهنده های خطیِ یونی، پروتونی با جریان بالا می پردازد و راه حل هایی برای بهینه نگهداشتن این کمیتها ارایه می دهد. بیرونگرایی یکی از کمیتهای اساسی باریکه هایِ ذرات باردار در شتابدهنده ها است که تاثیر قابل توجهی بر قیمت، هزینه و کاراییِ هر شتابدهند...
Low-noise, high-brightness, tunable source of picosecond pulsed light in the near-infrared and visible.
We have built a flexible source of picosecond pulsed light in both the near-infrared and visible spectral regions. A photonic crystal fiber (PCF) was pumped with a pulsed 1064 nm fiber laser to generate four-wave mixing (FWM) sidebands at 947 nm and 1213 nm. This process was seeded at the idler wavelength with a tunable diode laser to limit the spectral width of the sidebands to less than 0.5 n...
متن کاملHigh-energy picosecond OPO based on PPKTP.
Output energy of 1 mJ is obtained for the 380 ps long idler pulses at 2800 nm from a short cavity singly resonant 500 Hz optical parametric oscillator employing PPKTP and a near-diffraction-limited, single frequency, sub-nanosecond pump source at 1064 nm.
متن کاملHigh-power broadly tunable picosecond IR laser system for use in nonlinear spectroscopic applications
We developed a high-power tunable picosecond IR laser system suitable for nonlinear spectroscopic investiga tions. We employ a Ti:sapphire regenerative amplifier that produces 1.9-ps, 17-cm�1, 800-nm pulses at 1 kHz as a pump source. White-light generation in ethylene glycol and optical parametric amplification in potas sium titanyl phosphate are used to produce the IR pulses. The tuning rang...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Letters
سال: 2015
ISSN: 0146-9592,1539-4794
DOI: 10.1364/ol.40.005184