A rapid, new analytical method, based on liquid chromatography with UV detection, has been developed and utilised for the determination of biperiden hydrochloride in solid dosage forms. The chromatographic separation was performed a conventional C18 reversed phase column mobile composed acetonitrile-buffer mixture. Ultraviolet detection carried out at 205 nm. rapid extraction procedure using ultrasonic bath obtained good yield values analyte (≥ 98.4%). method specifically routine analysis forms applicable concentration range. linearity range investigated assay is between 2–6 μg mL−1. selective sufficiently precise. Thus, suitable biperiden.
منابع مشابه
HPLC determination of Chlorhexidine in dosage forms
The present paper describes the utilization of high-pressure liquid chromatography for determination of Chlorhexidine in complex samples of dosage forms. Chromatographic separation was performed on a cyanopropyl column using acetate buffer in the mixture of water and acetonitrile ((pT = 2:3) as the mobile phase. The linear dependence of the peak size on concentration of Chlorhexidine in the ran...
متن کاملA Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms
Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...
متن کاملA Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms
Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...
متن کاملDETERMINATION OF AMOXYCYLLIN AND CLAVULANIC ACID IN PHARMACEUTICAL DOSAGE FORMS BY HPLC WITH AMPEROMETRIC DETECTION
A simple and sensitive high performance liquid chromatographic method with electrochemical detection is described for the quantitative determination of the amoxycillin and clavulanic acid in pharmaceutical dosage forms. Separation of sample components occurs on a reversed phase C18 column with a mobile phase consisting of methanol-water-phosphate buffer. For the amperometric detection, the pote...
متن کاملApplication of Narrow-Bore HPLC Columns in Rapid Determination of Sildenafil Citrate in Its Pharmaceutical Dosage Forms
A special type of silica-based columns has been recently introduced into the market which is called narrow-bore columns. They have lower internal volume than the standard high-performance liquid chromatography (HPLC) columns and thus reduce the solvent consumption by almost 80%. A simple, accurate and environmentally friendly reversed phase- HPLC (RP-HPLC method) which could be used in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Dokladi na B?lgarskata akademiâ na naukite
سال: 2023
ISSN: ['2367-5535', '1310-1331']
DOI: https://doi.org/10.7546/crabs.2023.02.02