High spatial resolution scintillator dosimetry of synchrotron microbeams
نویسندگان
چکیده
منابع مشابه
Characterization of scintillator-based detectors for few-ten-keV high-spatial-resolution x-ray imaging.
PURPOSE High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scintillator-based detectors for this energy range and at high spatial frequencie...
متن کاملCharged-particle tracking with high spatial and temporal resolution using capillary arrays filled with liquid scintillator
We have developed a new technique that allows the trajectories of ionizing particles to be imaged with very high spatial and temporal resolution. This technique, developed for future experiments in high-energy physics, may also be applied in other fields. Central to the technique is a detector consisting of a bundle of thin, glass capillaries filled with a liquid scintillator of high refractive...
متن کاملBreast dosimetry using high-resolution voxel phantoms.
A computer model of X-ray mammography has been developed, which uses quasi-realistic high-resolution voxel phantoms to simulate the breast. The phantoms have 400 microm voxels and simulate the three-dimensional distributions of adipose and fibro-glandular tissues, Cooper's ligaments, ducts and skin and allow the estimation of dose to individual tissues. Calculations of the incident air kerma to...
متن کاملA high-spatial-resolution fiber-optic-coupled CMOS imager with novel scintillator for high-energy x-ray applications
A fast, high-spatial-resolution detector for high-energy microscopy work is presented. The detector uses a 2160 x 2560 CMOS chip for fast framing (up to 100 Hz in full-frame mode), coupled by a fiber optic taper to a scintillating Terbium-doped fiber optic plate for excellent stopping power even at high energies. The field of view is 7mm × 8.6mm with a resolution of 9 microns. The sensitivity i...
متن کاملA high spatial resolution synchrotron Mössbauer study of the Tazewell IIICD and Esquel pallasite meteorites
Metallic phases in the Tazewell IIICD iron and Esquel pallasite meteorites were examined using 57Fe synchrotron Mössbauer spectroscopy. Spatial resolution of ~10-20 μm was achieved, together with high throughput, enabling individual spectra to be recorded in less than 1 h. Spectra were recorded every 5-10 μm, allowing phase fractions and hyperfine parameters to be traced along transects of key ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scientific Reports
سال: 2019
ISSN: 2045-2322
DOI: 10.1038/s41598-019-43349-6