Design of Novel High Sensitive MEMS Capacitive Fingerprint Sensor
In this paper a new design of MEMS capacitive fingerprint sensors is presented. The capacitive sensor is made of two parallel plates with air gap. In these sensors, the capacitance changes is very important factor. It is caused by deformation of the upper electrode of sensor. In this study with making slots in upper electrode, using T-shaped protrusion on diaphragm in order to concentrate the f...
متن کاملHIGH SENSITIVE ABSOLUTE MEMS CAPACITIVE PRESSURE SENSOR IN SiGeMEMS PROCESS FOR BIOMEDICAL APPLICATIONS
A high sensitive CMOS Micro-electro-mechanical rectangular capacitive pressure sensor in SiGeMEMS process (Silicon Germanium Micro-electro-mechanical System process) is designed and analyzed. Polycrystalline Silicon Germanium (Poly-SiGe) having low fatigue and high strength is effectively used as the sensor diaphragm material to achieve better reliability. The designed perforated diaphragm clam...
متن کاملNew Design of Mems piezoresistive pressure sensor
The electromechanical analysis of a piezoresistive pressure microsensor with a square-shaped diaphragm for low-pressure biomedical applications is presented. This analysis is developed through a novel model and a finite element method (FEM) model. A microsensor with a diaphragm 1000 „m length and with thickness=400 µm is studied. The electric response of this microsensor is obtained with applyi...
متن کاملDesign of High Sensitivity and Linearity Microelectromechanical Systems Capacitive Tire Pressure Sensor using Stepped Membrane
This paper is focused on a novel design of stepped diaphragm for MEMS capacitive pressure sensor used in tire pressure monitoring system. The structure of sensor diaphragm plays a key role for determining the sensitivity of the sensor and the non-linearity of the output.First the structures of two capacitive pressure sensors with clamped square flatdiaphragms, with different thicknesses are inv...
متن کاملPolymer-based miniature flexible capacitive pressure sensor for intraocular pressure (IOP) monitoring inside a mouse eye.
This paper presents an ultra-thin and flexible polymer-based capacitive pressure sensor for intraocular pressure (IOP) monitoring in a mouse eye. Due to the size limitation of the anterior chamber in the mouse eye, a volume of approximately 700 × 700 × 150 μm(3) on a small substrate is available for the MEMS capacitive pressure sensor. Moreover, the sensor would ideally be easily injectable int...