High Precision 3D Single Molecule Microscopy Using the Double Helix Point Spread Function
نویسندگان
چکیده
منابع مشابه
Three-dimensional, single-molecule fluorescence imaging beyond the diffraction limit by using a double-helix point spread function.
We demonstrate single-molecule fluorescence imaging beyond the optical diffraction limit in 3 dimensions with a wide-field microscope that exhibits a double-helix point spread function (DH-PSF). The DH-PSF design features high and uniform Fisher information and has 2 dominant lobes in the image plane whose angular orientation rotates with the axial (z) position of the emitter. Single fluorescen...
متن کاملLocalizing and tracking single nanoscale emitters in three dimensions with high spatiotemporal resolution using a double-helix point spread function.
Three-dimensional nanoscale localization and tracking of dim single emitters can be obtained with a widefield fluorescence microscope exhibiting a double-helix point spread function (DH-PSF). We describe in detail how the localization precision quantitatively depends upon the number of photons detected and the z position of the nanoscale emitter, thereby showing a approximately 10 nm localizati...
متن کاملOptimal 3D single-molecule localization for superresolution microscopy with aberrations and engineered point spread functions.
Photo-activation localization microscopy is a far-field superresolution imaging technique based on the localization of single molecules with subdiffraction limit precision. Known under acronyms such as PALM (photo-activated localization microscopy) or STORM (stochastic optical reconstruction microscopy), these techniques achieve superresolution by allowing only a sparse, random set of molecules...
متن کاملExtraction of Depth Information in the Presence of Spherical Aberration Using Double-helix Point Spread Function Coding in 3d Fluorescence Microscopy Imaging
ABERRATION USING DOUBLE-HELIX POINT SPREAD FUNCTION CODING IN 3D FLUORESCENCE MICROSCOPY IMAGING Chrysanthe Preza, Sreya Ghosh, Ginni Grover, Sean Quirin, and Rafael Piestun Dept. of Electrical & Computer Eng., 206 Engineering Science Bldg., The University of Memphis, Memphis, TN 38152-3180, USA Dept. of Electrical and Computer Engineering, University of Colorado at Boulder, Boulder, Colorado 8...
متن کاملAccurate determination of CT point‐spread‐function with high precision
The measurement of modulation transfer functions (MTFs) in computed tomography (CT) is often performed by scanning a point source phantom such as a thin wire or a microbead. In these methods the region of interest (ROI) is generally placed on the scanned image to crop the point source response. The aim of the present study was to examine the effect of ROI size on MTF measurement, and to optimiz...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy and Microanalysis
سال: 2020
ISSN: 1431-9276,1435-8115
DOI: 10.1017/s1431927620018620