High Kinetic Energy Ion Mobility Spectrometry – Mass Spectrometry investigations of four inhalation anaesthetics: isoflurane, enflurane, sevoflurane and desflurane
نویسندگان
چکیده
Here we report the first High Kinetic Energy-Ion Mobility Spectrometry-Mass Spectrometric (HiKE-IMS-MS) investigations involving four fluranes; isoflurane, enflurane, sevoflurane and desflurane. Unlike standard (atmospheric pressure) IMS, HiKE-IMS can detect these compounds in positive ion mode. This is because its low-pressure environment (∼ 14 mbar) associated short drift times ensure reagent ions O2+• H3O+ are present reaction region, react with fluranes by dissociative charge proton transfer, respectively. However, their intensities very dependent on value of reduced electric field (E/N) applied humidity air region HiKE-IMS. In this paper explore potential use for quality control breath analysis fluranes. To help interpretation mobility spectra, hence ion-flurane chemistry occurring a was coupled to Time-of-Flight Mass Spectrometer so that m/z values both product contained within various peaks observed could be identified high level confidence. The dependencies as functions E/N (30–115 Td) reported. A number have been only under low conditions (H2O volume-mixing ratio ∼ 100 ppmv), including CHF2+ CHFCl + isoflurane CHF2+, CF3+ C3H2F5O+ desflurane, CH3O+, C3H3F4O+, C4H3F6O+ C4H3F6O+(H2O) sevoflurane. It interesting note CHFCl+ shorter than measured O2+•. explained resonant transfer processes region: O2 ⇌ O2+•.O2
منابع مشابه
The invention and development of enflurane, isoflurane, sevoflurane, and desflurane.
Thirty-six halogenated Me Et ethers have been synthesized for evaluation as volatile anesthetics. Eleven of the ethers were too unstable to test, and, of the remaining 25, 13 had promising anesthetic properties in mice and are suitable for study in larger animals. Those ethers having one H with at least 2 halogens other than F or 2 or more H with at least one Br or Cl were the best anesthetics.
متن کاملIon Mobility Mass Spectrometry
for more complex analysers for automated sample processing and plant control. The separation time will continue to decrease; in the past there has been limited interest in fast separations but this could change as automated sample processing is developed. Increasing use of coupled techniques such as GC-GC, liquid chromatography-GC, and supercritical Suid chromatography-GC for the separation of ...
متن کاملElectrospray ionization high-resolution ion mobility spectrometry-mass spectrometry.
A hybrid atmospheric pressure ion mobility spectrometer is described which exhibits resolving power approaching the diffusion limit for singly and multiply charged ions (over 200 for the most favorable case). Using an electrospray ionization source and a downstream quadrupole mass spectrometer with electron multiplier as detector, this ESI-IMS-MS instrument demonstrates the potential of IMS for...