High-energy x-ray nanotomography introducing an apodization Fresnel zone plate objective lens

نویسندگان

چکیده

In this study, high-energy x-ray nanotomography (nano-computed tomography, nano-CT) based on full-field microscopy was developed. Fine two-dimensional and three-dimensional (3D) structures with linewidths of 75 nm–100 nm were successfully resolved in the energy range 15 keV–37.7 keV. The effective field view ∼60 µm, typical measurement time for one tomographic scan 30 min–60 min. optical system established at 250-m-long beamline 20XU SPring-8 to realize greater than 100× magnification images. An apodization Fresnel zone plate (A-FZP), specifically developed imaging, used as objective lens. design A-FZP imaging is discussed, its diffraction efficiency distribution evaluated. spatial resolutions energies keV, 20 37.7 keV examined using a test object, measured values are shown be good agreement theoretical values. High-energy nano-CT combination micro-CT applied 3D multiscale imaging. entire bodies bulky samples, ∼1 mm diameter, micro-CT, nondestructive observation regions interest. Examples CT measurements involving carbon steel, mouse bones, meteorite discussed.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Demonstration of 12 nm resolution Fresnel zone plate lens based soft x-ray microscopy.

To extend soft x-ray microscopy to a resolution of order 10 nm or better, we developed a new nanofabrication process for Fresnel zone plate lenses. The new process, based on the double patterning technique, has enabled us to fabricate high quality gold zone plates with 12 nm outer zones. Testing of the zone plate with the full-field transmission x-ray microscope, XM-1, in Berkeley, showed that ...

متن کامل

Phase Fresnel Lens Development for X-ray & Gamma-ray Astronomy

Observations in the hard X-ray and gammaray energy regimes are constrained by limited sensitivity and angular resolution. Significant gains could be made if these high-energy photons could be concentrated from a large area onto a small detector element and if diffraction-limited measurements could be obtained. Furthermore, the angular resolution in the gamma-ray band would be superior to that p...

متن کامل

X-ray Fourier transform holography by amplitude-division-type Fresnel zone plate interferometer.

A two-block X-ray Fresnel zone plate system forms two-beams - a plane wave and a spherical wave - which interfere at the focal distance of the virtual source of the spherical wave. An object placed in the path of the plane wave forms an object wave and the spherical wave is the reference wave. The recorded intensity distribution is the Fourier transform hologram of the object. Analytical and nu...

متن کامل

Sub-25-nm laboratory x-ray microscopy using a compound Fresnel zone plate.

Improving the resolution in x-ray microscopes is of high priority to enable future applications in nanoscience. However, high-resolution zone-plate optics often have low efficiency, which makes implementation in laboratory microscopes difficult. We present a laboratory x-ray microscope based on a compound zone plate. The compound zone plate utilizes multiple diffraction orders to achieve high r...

متن کامل

Two-step hard X-ray focusing combining Fresnel zone plate and single-bounce ellipsoidal capillary.

A two-step focusing set-up combining a Fresnel zone plate with an ellipsoidal capillary is presented. It is shown that, in addition to the anticipated gain in flux, the employment of the prefocusing micro-optic makes optimal use of the elliptical shape of the capillary by almost eliminating aberrations. A small cross section of the prefocused beam allows a tiny fraction of the capillary surface...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Review of Scientific Instruments

سال: 2021

ISSN: ['1089-7623', '1527-2400', '0034-6748']

DOI: https://doi.org/10.1063/5.0020293