High-Efficiency Free-Electron Laser Results
نویسندگان
چکیده
منابع مشابه
Design Considerations for a High-Efficiency High-Gain Free-Electron Laser for Power Beaming
Power beaming from ground-based systems to space-based platforms has been proposed by a number of researchers as a means of delivering energy to orbiting satellites and stations. This paper considers the use of a seeded high-gain highefficiency Free-Electron Laser (FEL) amplifier based on a conventional linac as the source for power beaming. While the wall-plug efficiency of a single pass FEL i...
متن کاملHigh-gain Harmonic-generation Free-electron Laser
A high-gain harmonic-generation free-electron laser is demonstrated. Our approach uses a laser-seeded free-electron laser to produce amplified, longitudinally coherent, Fourier transform-limited output at a harmonic of the seed laser. A seed carbon dioxide laser at a wavelength of 10.6 micrometers produced saturated, amplified free-etectron laser output at the second-harmonic wavelength, 5.3 mi...
متن کاملHigh-gain harmonic-generation free-electron laser
A high-gain harmonic-generation free-electron laser is demonstrated. Our approach uses a laser-seeded free-electron laser to produce amplified, longitudinally coherent, Fourier transform-limited output at a harmonic of the seed laser. A seed carbon dioxide laser at a wavelength of 10.6 micrometers produced saturated, amplified free-electron laser output at the second-harmonic wavelength, 5.3 mi...
متن کاملSingle-pass High-gain Free Electron Laser Electron Beam Diagnostics
Consensus reached in the last few years that fourth generation light source will most likely be a X-ray or a UV coherent source based on single-pass high-gain free electron laser (FEL), such as Self Amplified Spontaneous Emission (SASE), or seeded high-gain harmonic -generation (HGHG) free electron lasers. High -gain (> 10) required for single-pass FEL puts great constrain on the quality of ele...
متن کاملNew results of the high-gain harmonic generation free-electron laser experiment
We report on the experimental investigation of high-gain harmonic generation carried out at the Accelerator Test Facility at Brookhaven National Laboratory. A seed CO2 laser at a wavelength of 10.6mm was used to generate FEL output at a 5.3-mm wavelength. The duration of the output pulse was measured using a second-harmonic intensity autocorrelator, and the coherence length was measured using a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1983
ISSN: 0018-9499
DOI: 10.1109/tns.1983.4336575