HEMATOLOGIC AUTOMATION BY USE OF CONTINUOUS FLOW SYSTEMS

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automation of a fixed-bed continuous–flow reactor

This paper describes the design and operation of a laboratory plant with a fixed-bed continuous-flow reactor, fully automated and controlled from a personal computer. The automated variables include two gas flows, one liquid flow, six temperatures, two pressures, one circulation of a cooling liquid, and 10 electrovalves. An adaptive-predictive control system was used. The chemical process chose...

متن کامل

Continuous-flow automation of the Lactobacillus casei serum folate assay.

A method is described for the continuous-flow automation of the serum folate assay using Lactobacillus casei. The total incubation period is approximately four hours. The growth response of the organism to folate is estimated by measuring the rate of reduction of 2,3,5-triphenyl tetrazolium chloride (TTC). A simple continuous culture apparatus is used to grow the inoculum. Supplementation of th...

متن کامل

Interference by other halides in the automation of chloride. Contributions to the general methodology of continuous flow systems.

An investigation was undertaken to study the factors which cause grossly elevated values in an automated procedure for chloride when the sample is contaminated with bromide. The questioned mercuric thiocyanate method of the autoanalyzer was compared to a similar system utilizing mercuric 2, 4, 6-tripyridyl-s-triazine as a substitute ligand source in the chloride exchange system. It was determin...

متن کامل

Continuous-flow system for automation of latex immunoassay by particle counting.

Latex immunoassay is a nonisotopic method based on agglutination, by protein, of calibrated latex particles coated with a specific antibody. The assay has been automated in a simple continuous-flow system by incubating the reaction mixture in a heated mixing coil for 25 min and measuring the agglutination with a cell counter. No external shaking of the latex suspension and no additional reagent...

متن کامل

Calibration in process monitoring by using unsegmented continuous-flow systems

An overview is presented of the different aspects of the role of analytical chemistry in process monitoring and control. On-line monitoring is currently the most attractive option in this area, especially with unsegmented-flow techniques. In addition to allowing automation of these systems, the variety of ways in which calibration and recalibration can be performed allows their adaptation to an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Histochemistry & Cytochemistry

سال: 1974

ISSN: 0022-1554,1551-5044

DOI: 10.1177/22.7.707