منابع مشابه
Investigation on Turbulent Nanofluid Flow in Helical Tube in Tube Heat Exchangers
In this study, the thermal characteristics of turbulent nanofluid flow in a helical tube in the tube heat exchanger (HTTHE) were assessed numerically through computational fluid dynamics (CFD) simulation. The findings of both the turbulent models: realizable k-epsion (k-ε) and re-normalisation group (RNG) k-epsilon were compared. The temperature distribution contours show that realizable and RN...
متن کاملNumerical Comparison of Turbulent Heat Transfer and Flow Characteristics of SiO2/Water Nanofluid within Helically Corrugated Tubes and Plain Tube
Turbulent heat transfer in Helically Corrugated Tubes (HCT) was numerically investigated for pure water and SiO2 nanofluid using Computational Fluid Dynamics (CFD). This study was carried out for different corrugating pitches (5, 7, 8 mm) and heights (0.5, 0.75, 1.25 mm) at various Reynolds numbers ranging from 5000 to 13300. The effect of nanoparticles on heat transfer augmentation for plain t...
متن کاملAn experimental investigation of turbulent flow heat transfer through tube with rod-pin insert
An experimental investigation has been carried out to study the turbulent flow heat transfer and to determine the pressure drop characteristics of air, flowing through a tube with insert. An insert of special geometry is used inside the tube. The test section is electrically heated, and air is allowed to flow as the working fluid through the tube by means of a blower. Air velocity, air inlet an...
متن کاملInvestigation of Heat Transfer Coefficient of Ethylene Glycol/ Graphenenanofluid in Turbulent Flow Regime
In the present work, graphene was synthesized by chemical vapor deposition (CVD) method. The structure of graphene was then confirmed by X-Ray diffraction (XRD) and scanning electron microscope (TEM) images. After that, mixed acid method (H2<span style=...
متن کاملHeat Transfer from a Tube Bank in Cross Flow in a Duct
An experimental investigation on heat transfer coefficient is presented from three horizontal tubes in a vertical array in a duct for 500<ReD<6000. A mass transfer measuring technique based on psychrometry chart is used to determine heat transfer coefficient. The diameter of the tubes is 11 mm each spaced 40 mm apart and in-line pitch ratio varies 
in the range 0.055<D/W<0.22. The experimen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied Scientific Research
سال: 1956
ISSN: 0003-6994
DOI: 10.1007/bf03185034