We processed applesauce, tomato juice, and cranberries in pint jars in a boiling water canner to test thermal processing theories against home canning of high-acid foods. For each product, thermocouples were placed at various heights in the jar. Values for f h (heating), f cl (cooling), and F 82.2°C (lethality) were determined for each thermocouple location, and did not depend substantially on ...

متن کامل

Transient heat flux measurement using a surface junction thermocouple

A new form of surface junction thermocouple sensor has been developed and tested. The novel feature of the design is the use of a tapered fit between two coaxial thermocouple elements to form a thin, robust junction. The gauge has a response time on the order of 1 ms and is suitable for measuring large transient heat fluxes in hypervelocity wind tunnels. Asymptotic analysis is used to demonstra...

متن کامل

Computer-Based On-Line Assessment of Sterilizing Value and Heat Distribution in Retort for Canning Process

Heating process for food is of importance to the consumers since it is considered to be one of food preservation techniques. Under these techniques food can be stored or edible within a long period of time. One of them which require heat treatment is sterilization process. Thermal sterilization of prepackaged canned foods in retort has been the most widely used during the twentieth century. Typ...

متن کامل

Direct thermocouple measurements of temperature rise and heat conduction in the rabbit retina.

For a given burn, a greater dose was required to raise the temperature to the same level tuhen the spectral distribution of the source included both the visible and the near infrared. Temperature rises compatible with steam production have not been obtained even for very intense burns. In cases of retinal explosion the temperature rose above 40° C, which when added to the body temperature gave ...

متن کامل

Thermocouple Measurement

In 1822, Thomas Seebeck, an Estonian physician, accidentally joined semicircular pieces of bismuth and copper (Figure 1) while studying thermal effects on galvanic arrangements. A nearby compass indicated a magnetic disturbance. Seebeck experimented repeatedly with different metal combinations at various temperatures, noting relative magnetic fi eld strengths. Curiously, he did not believe that...

متن کامل