Heat and Mass Transfer Coefficients in Double Tube Cooler Condenser
نویسندگان
چکیده
منابع مشابه
Heat and Mass Transfer Coefficients Under Frost Conditions In A Finned-Tube Evaporator
The objectives of this study are to provide experimental data and a correlation that can be used in the optimal design of an evaporator under frost conditions. In the present study, we tested both a single stage and a two-stage evaporator with a variation of operating parameters and fin geometry under frost conditions. The effects of tube space and fin alignment on the heat transfer performance...
متن کاملEffect of conjugate heat transfer in designing thermoelectric beverage cooler
Peltier technology opens new opportunities for special applications. In the current project, this technology was applied to design and fabricate a portable thermoelectric beverage cooler and thermoelectric cup. The simulation and results of the experiment showed that the common beverage cooler is not a suitable design for ignoring the effect of natural convection in cooling. In our thermoel...
متن کاملEffect of conjugate heat transfer in designing thermoelectric beverage cooler
Peltier technology opens new opportunities for specialapplications. In the current project, this technology was appliedto design and fabricate a portable thermoelectric beveragecooler and thermoelectric cup. The simulation and results of theexperiment showed that the common beverage cooler is not asuitable design for ignoring the effect of natural convection in<br ...
متن کاملThe effect of Geometrical parameters on heat transfer coefficient in helical double tube exchangers
Helical coil heat exchangers are widely used in industrial applications ranging fromcryogenic processes, air-conditioning, and nuclear reactors to waste heat recovery due totheir compact size and high heat transfer coefficient. In this kind of heat exchangers, flowand heat transfer are complicated. This paper reports a numerical investigation of theinfluence of different parameters such as coil...
متن کاملDetermination of Refrigerant Path Number for Fin-tube Condenser Considering Heat Transfer Performance and Pumping Power
Fin-tube heat exchangers are widely used in air-conditioners and heat pumps, which are constructed with a lot of tubes. Refrigerant circuit of heat exchanger with numerous pipe can be constructed by many methods. Refrigerant circuit design is usually determined designer’s experience and case by case test without guides. The number of path affects largely on heat exchanger performance. In this p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The chemical machinerey
سال: 1952
ISSN: 0368-4784
DOI: 10.1252/kakoronbunshu1937.16.338