Guidelines for compatibility testing in hospital blood banks
نویسندگان
چکیده
منابع مشابه
Guidelines for compatibility procedures in blood transfusion laboratories.
SECTION 1 INTRODUCTION 1.1 Purpose of the guidelines The effective development and maintenance of satisfactory standards in pretransfusion testing requires a structured approach in the adoption of a quality system. Technical errors, clerical errors, the use of nonvalidated techniques or equipment and noncompliance with established procedures may result in missed incompatibilities and immediate ...
متن کاملGuidelines for pre-transfusion compatibility procedures in blood transfusion laboratories
1.1. Purpose of pre-transfusion guidelines. Technical errors and/or inappropriate test systems or administrative errors may result in immediate and delayed haemolytic transfusion reactions. The purpose of these guidelines, which replace those previously published (BCSH, 1991a), is to define organizational, documentation and technical procedures undertaken in hospital or Regional Transfusion Cen...
متن کاملGuidelines for pre-transfusion compatibility procedures in blood transfusion laboratories. BCSH Blood Transfusion Task Force.
British Committee for Standards in Haematology C. Milkins,1 J. Berryman,2 C. Cantwell,3 C. Elliott,4 R. Haggas,5 J. Jones,6 M. Rowley,3,7 M. Williams8 & N. Win9 1UK NEQAS (BTLP), West Herts Hospitals NHS Trust, Watford, UK, 2Department of Blood Transfusion, University College London Hospitals, NHS Foundation Trust, London, UK, 3Department of Blood Transfusion, Imperial College Healthcare NHS Tr...
متن کاملIn vivo red blood cell compatibility testing using indium-113m tropolone-labeled red blood cells.
In vivo radionuclide crossmatch is a method for identifying compatible blood for transfusion when allo- or autoantibodies preclude the use of conventional crossmatching techniques. A technique for labeling small volumes of donor red blood cells with [113mIn]tropolone is reported. The use of 113mIn minimizes the accumulation of background radioactivity and the radiation dose especially so when m...
متن کاملDirect compatibility testing.
Despite the rapid development of knowledge it still remains fundamental that mistakes within the ABO and Rhesus systems are responsible for virtually all fatal mismatched transfusions. It therefore cannot be too highly stressed that the careful preliminary grouping of the bloods of all patients for transfusion is of prime importance, irrespective of whether there is a previous record of their b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical & Laboratory Haematology
سال: 1987
ISSN: 0141-9854,1365-2257
DOI: 10.1111/j.1365-2257.1987.tb00099.x