Glucose-stat, a glucose-controlled continuous culture
نویسندگان
چکیده
منابع مشابه
JAK-STAT signaling and myocardial glucose metabolism
JAK-STAT signaling occurs in virtually every tissue of the body, and so does glucose metabolism. In this review, we summarize the regulation of glucose metabolism in the myocardium and ponder whether JAK-STAT signaling participates in this regulation. Despite a paucity of data directly pertaining to cardiac myocytes, we conclude that JAK-STAT signaling may contribute to the development of insul...
متن کاملGlucose oxidase method for continuous automated blood glucose determination.
A glucoseoxidase-peroxidasemethod for continuous automated monitoring of blood glucosehas been developed.The responseis linear over the range 0-800 mg/100 ml. Sensitivity can be maintained for 24 hr or longer and can be restored by rinsing the analytic system with sulfuric acid to permit studies of longer than 48 hr in duration. A precisionof ± 1% can be maintained between rinsesfor samplescont...
متن کاملFeasibility of fully automated closed-loop glucose control using continuous subcutaneous glucose measurements in critical illness: a randomized controlled trial
INTRODUCTION Closed-loop (CL) systems modulate insulin delivery according to glucose levels without nurse input. In a prospective randomized controlled trial, we evaluated the feasibility of an automated closed-loop approach based on subcutaneous glucose measurements in comparison with a local sliding-scale insulin-therapy protocol. METHODS Twenty-four critically ill adults (predominantly tra...
متن کاملContinuous glucose monitoring and pumps.
BACKGROUND While multiple daily insulin injections remains the state-of-the-art treatment for type 1 diabetes, continuous subcutaneous insulin infusion (CSII) has become increasingly popular in recent years. Up to 40% of people with type 1 diabetes in younger age groups are now using CSII. Very recently, continuous glucose monitoring (CGM) has been developed. This technology now has proven bene...
متن کاملToward a Continuous Intravascular Glucose Monitoring System
Proof-of-concept studies that display the potential of using a glucose-sensitive hydrogel as a continuous glucose sensor are presented. The swelling ratio, porosity, and diffusivity of the hydrogel increased with glucose concentration. In glucose solutions of 50, 100, 200, and 300 mg/dL, the hydrogel swelling ratios were 4.9, 12.3, 15.9, and 21.7, respectively, and the swelling was reversible. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied and Environmental Microbiology
سال: 1991
ISSN: 0099-2240,1098-5336
DOI: 10.1128/aem.57.4.918-923.1991