Gas-Liquid Oxygen Transfer Characteristics in an Aerated Biofilter

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Oxygen Transfer in a Biological Aerated Filter

The City of San Diego (City) operates the Point Loma Wastewater Treatment Plant (PLWTP) which can normally treat up to 240 million gallons per day (MGD) of chemically enhanced primary treated (CEPT) effluent for ocean disposal. The City wanted to understand the performance capabilities of Biological Aerated Filters (BAFs) in treating CEPT effluent to secondary standards. To this end, the City c...

متن کامل

Mass transfer in a membrane aerated biofilm.

We present experimental results of mass transfer of a non reactive tracer gas (neon) measured in aerobic heterotrophic biofilm developed from activated sludge. Biofilms are grown in various hydrodynamic conditions and the effective diffusivity is used to quantify the mass transfer through the biofilm. Beyond some cross-flow conditions, the effective diffusivity through the biofilm seems larger ...

متن کامل

Overcoming the Gas–Liquid Mass Transfer of Oxygen by Coupling Photosynthetic Water Oxidation with Biocatalytic Oxyfunctionalization

Gas-liquid mass transfer of gaseous reactants is a major limitation for high space-time yields, especially for O2 -dependent (bio)catalytic reactions in aqueous solutions. Herein, oxygenic photosynthesis was used for homogeneous O2 supply via in situ generation in the liquid phase to overcome this limitation. The phototrophic cyanobacterium Synechocystis sp. PCC6803 was engineered to synthesize...

متن کامل

Gas-liquid Flow in a Rectangular Partially Aerated Bubble Column: Combined Effect of Aspect Ratio and Superficial Gas Velocity

Bubble columns are multiphase equipments used to bring into contact gas and liquid phases. Gas, that constitutes the dispersed phase, is distributed at the bottom of the column and rises as bubbles through the liquid that constitutes the continuous phase. They are frequently used in the industry although the partial knowledge of the fluid dynamics of the gas-liquid flow have hindered a complete...

متن کامل

Study on Mass Transfer Enhancement in a Gas-Liquid System Using Nanomaterials

The main objective of this paper is to examine the effect of nanomaterials on mass transfer coefficient in bubble type absorption of carbon dioxide by experiment. The absorption process is carried out in a bubble column and in room temperature. Mass transfer coefficient, saturated concentration of CO2, and gas holdup are determined in this system. The kinds of nanomaterials, the concentrations ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Japan journal of water pollution research

سال: 1991

ISSN: 0387-2025

DOI: 10.2965/jswe1978.14.623