FTIR AND UV IN STEEL PIPELINE COATING APPLICATION
نویسندگان
چکیده
منابع مشابه
Occupational asthma in a steel coating plant.
An outbreak of occupational asthma, of unknown cause and extent, was detected in a steel coating plant. In 1979 a cross-sectional study which defined occupational asthma in terms of respiratory symptoms detected 21 people with suggestive symptoms among the 221 studied. They all worked in the coating shop, but the plastic coatings used at the plant contained many potential sensitising agents tha...
متن کاملTitanium-Aluminum Oxide Coating on Aluminized Steel
In this study, a plasma electrolytic oxidation (PEO) process was used to form titanium-aluminum oxide coating on aluminized steel. The present work was mainly to study the effects of treatment time of PEO process on properties of the titanium coating. A potentiodynamic polarization corrosion test was employed to investigate the corrosion resistance of the coating. The friction coefficient and w...
متن کاملFabrication of Nanodiamond Coating on Steel
The hardness, heat conductivity and low friction coefficient of microcrystalline diamond make it a suitable candidate for tribological applications. However, its roughness and high deposition temperature pose significant obstacles to these applications. We have successfully grown nanocrystalline diamond on steel at 400 °C by hot-filament chemical vapor deposition by employing a CrN interfacial ...
متن کاملCan-Printing Process Uses UV-Curable Coating
Approximately 100 billion aluminum cans are produced annually, mainly for the beverage industry. Early technologies for decorating the cans often used solvent-based coatings containing solvents at concentrations of -70% to 75% by volume (Randall 1992). The solvent composition was typically a mixture of aliphatic hydrocarbons, aromatics, ethers, cellosolves, and acetates. Unfortunately, this met...
متن کاملApplication of Co-Ni-P coating on grain-oriented electrical steel
An electroless plating of Co-Ni-P was applied to a grain-oriented electrical steel substrate resulting in a power loss improvement of approximately 9-11 %. The mean thickness of the coating was found to be 2.15±0.15 μm from Environmental Scanning Electron Microscope (ESEM) images. Shifts of the magnetostriction stress sensitivity curves showed that stress was acting on the substrate corroborate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of GEOMATE
سال: 2020
ISSN: 2186-2982,2186-2990
DOI: 10.21660/2020.69.9427