Foundation with increased load bearing base capacity
نویسندگان
چکیده
Along with other advanced geotechnical technologies for the exploration of underground space, electro-discharge technology (EDT technology) is one fundamental in field construction auger-injection microcircuits, as well transformation properties foundation soils weak physical and mechanical characteristics. At same time, having significant differences compared to methods subsurface development buildings structures, EDT has a number advantages, such as: 1) increased specific soil load-bearing capacity; 2) constructability auger piles any conditions; 3) possibility works performance under restricted conditions. As basic structure new technologies, it large scientific research potential purposes introducing into modern construction.
منابع مشابه
Study on Bearing Capacity of Prestressed Pipe Pile Foundation Under Horizontal Load
Received: June 12, 2017 Revised: October 24, 2017 Accepted: November 03, 2017 Abstract: Background and Objective: Prestressed high strength concrete pipe pile (PHC) shows brittle fracture when subjected to more than its own bearing capacity. Therefore, the non-prestressed steel bar is added to the PHC pipe pile, that is, the mixed reinforced pipe pile (PRC). The mechanical behavior of PRC group...
متن کاملThe effect of short fiber composite base on microleakage and load-bearing capacity of posterior restorations
Objectives: To determine the marginal microleakage of Class II restorations made with different composite base materials and the static load-bearing capacity of direct composite onlay restorations. Methods: Class II cavities were prepared in 40 extracted molars. They were divided into five groups (n = 8/group) depending on composite base material used (everX Posterior, SDR, Tetric EvoFlow). Aft...
متن کاملHorizontal Bearing Capacity of A New Bucket Foundation with Partial Inclined Wall
The traditional bucket foundation use vertical wall, which like a cup is buried upside down in seabed. A new bucket foundation with partial inclined wall has been proposed in this article. Based on limit equilibrium analysis of threedimensional stress state of foundation, the calculation method of the horizontal bearing capacity of the new bucket foundation has been deduced, which has been veri...
متن کاملUltimate Bearing Capacity of Eccentrically Loaded Strip Foundation on Sand Reinforced with Geogrids
This paper reports the results of model loading tests performed on an eccentrically loaded strip foundation supported by multi-layered geogrid-reinforced sand. Only one type of geogrid and sand at one relative density of compaction were considered. Based on the present laboratory test results, an empirical relationship for the reduction factor has been developed. This relationship can be used t...
متن کاملBase Level Evaluation in Buildings with Different Foundation Levels by Soil-foundation-structure Interaction
The base level is among the effective parameters in determining the seismic force on a structure, if the equivalent-static method is used for analyzing a structure. It is obvious that the base level is located on foundation in buildings in which foundation is built in a single level and there is not any interaction between the structure's walls and the soil; however, in some buildings which hav...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: E3S web of conferences
سال: 2021
ISSN: ['2555-0403', '2267-1242']
DOI: https://doi.org/10.1051/e3sconf/202127403015