Force-velocity test on a stationary cycle ergometer: methodological recommendations
نویسندگان
چکیده
منابع مشابه
Reproducibility of estimated optimal peak output using a force-velocity test on a cycle ergometer
The current study aimed to examine the reproducibility of estimated peak power and estimated pedal velocity in a multi-trial 10-s all-out cycling test among adult athletes (n = 22; aged 23.50±4.73 years). Stature, sitting height and body mass were measured. Leg length was estimated as stature minus sitting height. Body volume was obtained from air displacement plethysmography and was subsequent...
متن کاملReliability of a 2-bout exercise test on a wattbike cycle ergometer.
PURPOSE To determine the intraday and interday reliability of a 2 × 4-min performance test on a cycle ergometer (Wattbike) separated by 30 min of passive recovery (2 × 4MMP). METHODS Twelve highly trained cyclists (mean ± SD; age = 20 ± 2 y, predicted VO2max = 59.0 ± 3.6 mL · kg-1 · min-1) completed six 2 × 4MMP cycling tests on a Wattbike ergometer separated by 7 d. Mean power was measured t...
متن کاملThe reliability of a 30-s sprint test on the Wattbike cycle ergometer.
PURPOSE To determine the reliability of a 30-s sprint cycle test on the Wattbike cycle ergometer. METHODS Over 3 consecutive weeks, 11 highly trained cyclists (mean ± SD; age 31 ± 6 y, mass 74.6 ± 10.6 kg, height 180.5 ± 8.1cm) completed four 30-s maximal sprints on a Wattbike ergometer after a standardized warm-up. The sprint test implemented a "rolling start" that consisted of a 60-s preloa...
متن کاملEffects of Beetroot Juice Supplementation on a 30-s High-Intensity Inertial Cycle Ergometer Test
Background: Beetroot juice (BJ) is rich in inorganic nitrates and has proved effective at increasing blood nitric oxide (NO) levels. When used as a supplement BJ has shown an ergogenic effect on cardiorespiratory resistance exercise modalities, yet few studies have examined its impact on high intensity efforts. Objective: To assess the effects of BJ intake on anaerobic performance in a Wingate ...
متن کاملValidation of a new cycle ergometer.
The purpose of this study was to test the concurrent validity of the ICBE compared to the Monark(®) cycle ergometer by indirect dynamic calibration. 42 men were randomly submitted to 2 maximal stress tests with increments of 50 W at 2-min intervals. One test was performed on the Monark(®) bicycle (834/E) and the other on the ICBE. Cardiovascular, perceived exertion and hemodynamic responses wer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Applied Physiology
سال: 2018
ISSN: 8750-7587,1522-1601
DOI: 10.1152/japplphysiol.00719.2017