Foetal acid-base status in clinical foetal distress and high risk cases
نویسندگان
چکیده
منابع مشابه
Foetal acid-base status in clinical foetal distress and high risk cases.
The acid-base balance in 307 Chinese patients in labour was studied in Tsan Yuk Hospital, Hong Kong over a 15-month period. Fifty-six of these were normal cases, 200 cases exhibited clinical signs of foetal distress and the other fifty-one were high risk cases. The results showed that cases of clinical foetal distress had a significantly lower foetal pH than that in the normal control group. Of...
متن کاملFoetal Acid-base Balance at Caesarean Section
Sir,—In the Correspondence section of the Journal (1972, 44, 233) Dr Marx mentioned that foetal acid-base values obtained from umbilical artery blood at Caesarean sections did not correlate with the condition of the newborn infant at birth. I should like to provide evidence that acid-base values of umbilical artery blood are not reliable at Caesarean sections under general anaesthesia. We measu...
متن کاملFoetal acid-base balance at Caesarean section.
Sir,—In the Correspondence section of the Journal (1972, 44, 233) Dr Marx mentioned that foetal acid-base values obtained from umbilical artery blood at Caesarean sections did not correlate with the condition of the newborn infant at birth. I should like to provide evidence that acid-base values of umbilical artery blood are not reliable at Caesarean sections under general anaesthesia. We measu...
متن کاملFoetal distress and neonatal asphyxia.
PART I WITH improvements in maternal obstetric management, it is possible to turn increasingly to the care of the child, especially throughout labour and in the immediate postnatal period, when the child is at greatest risk. Though the signs considered to indicate foetal distress have been recognized for many years, it is, however, also necessary to assess the urgency and the severity of the th...
متن کاملCorrelation between the foetal acid-base status and the Apgar score.
The foetal pH values of eighty-eight cases delivered within 30 min after foetal blood sampling were correlated with the 1-min Apgar score. With a pH of 7.20 or above the error of prediction was 1'3%o. The error in cases with pH below 7.20 was 54'5/. Significantly higher pH and lower A base deficit were present in the low foetal pH group in vigorous, as opposed to depressed infants, suggesting t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Postgraduate Medical Journal
سال: 1972
ISSN: 0032-5473
DOI: 10.1136/pgmj.48.556.91