منابع مشابه
DNA Damages on Blood Cells After Cardiac Magnetic Resonance Imaging
Introduction: Along with the increased use of cardiac imaging at clinics there is increased attention to the potential risks related to the methods used like magnetic resonance (MR) and it cannot be ruled out that MR can alter DNA structure. The aim of this review is to assess the impact of routine cardiac magnetic resonance (CMR) scanning on DNA damages in human T lymphocytes....
متن کاملEnergy window setting for optimum Tl-201 cardiac imaging [Persian]
Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is ve...
متن کاملCardiac and Hepatic T2*-Weighted Magnetic Resonance Imaging
Abstract Background Iron overload is the main transfusion related side effects in patients with transfusion dependent hemoglobinopathies. Severe iron deposition in tissues leads to organ dysfunction. Many organs can be affected such as heart, liver, and endocrine organs. Cardiac failure and liver fibrosis are the consequent of Iron overload in transfusion dependent hemoglobinopathy. Magne...
متن کاملSimultaneous measurement of water flow velocity with fluorescent and speckle imaging technique
The average velocity of water flow has been simultaneously measured with fluorescent and speckle imaging methods. The measured velocities with two methods are in good agreement with each other and it confirms that the speckle imaging method can be used as a confident method to measure the velocity of water flow in a dry leaf. Also the velocity of water flow through thick and thin xylems of a le...
متن کاملHyperspectral Imaging of Fluorescent Dyes
Resonon utilizes line-scan spectral imaging, where a scene is limited to one dimension with a slit, and then imaged off a diffraction grating to obtain spectral information for each pixel along the slit. A second spatial dimension is obtained by scanning the object as multiple frames are collected. Here, electrophoresis was used as the scanning mechanism, as illustrated in Figures 1 and 2. Prot...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Circulation
سال: 2007
ISSN: 0009-7322,1524-4539
DOI: 10.1161/circulationaha.106.655936