Flame temperature reconstruction through a multi-plenoptic camera technique
نویسندگان
چکیده
منابع مشابه
Focused Plenoptic Camera and Rendering Focused Plenoptic Camera and Rendering
Plenoptic cameras, constructed with internal microlens arrays, capture both spatial and angular information, i.e., the full four-dimensional radiance, of a scene. The design of traditional plenoptic cameras assumes that each microlens image is completely defocused with respect to the image created by the main camera lens. As a result, only a single pixel in the final image is rendered from each...
متن کاملPlenoptic Camera Resolution
To resolve the low resolution problem of Plenoptic cameras we analyze optical signal sampling at frequencies above Nyquist. The resultant aliased signal is superresolved interleaving the array of microimages, thus cancelling the aliasing components. The rendered image can reach full sensor resolution. OCIS codes: (100.6640) Superresolution; (110.1758) Computational imaging; (110.5200) Photograp...
متن کاملOptimization of Spectrally Coded Mask for Multi-modal Plenoptic Camera
We introduce a framework to optimize the spatial layout of a spectral filter mask inserted into the aperture of a plenoptic camera. The optimization merit function evaluates end-to-end system performance, including spectral crosstalk at the sensor caused by lens aberrations and diffraction effects. We use the example of a Bayer pattern to illustrate the effects of optimized filter partitions on...
متن کاملEvaluation of multispectral plenoptic camera
Plenoptic cameras enable capture of a 4D lightfield, allowing digital refocusing and depth estimation from data captured with a compact portable camera. Whereas most of the work on plenoptic camera design has been based a simplistic geometric-optics-based characterization of the optical path only, little work has been done of optimizing end-to-end system performance for a specific application. ...
متن کاملFocused plenoptic camera and rendering
bstract. Plenoptic cameras, constructed with internal microlens rrays, capture both spatial and angular information, i.e., the full 4-D adiance, of a scene. The design of traditional plenoptic cameras ssumes that each microlens image is completely defocused with espect to the image created by the main camera lens. As a result, nly a single pixel in the final image is rendered from each microlen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Measurement Science and Technology
سال: 2019
ISSN: 0957-0233,1361-6501
DOI: 10.1088/1361-6501/ab2e98