Fire extinguishing system in large underground garages
نویسندگان
چکیده
منابع مشابه
Underground Fire Rollback Simulation in Large Scale Ventilation Models
A feasible solution is to create a single network model to simulate both the large scale ventilation model and the smaller scale rollback behavior. This can potentially be achieved by creating a detailed high density three-dimensional mesh of pathways bounded by the airway around a fire which then feeds into the simpler network of a large scale ventilation model. The high density mesh allows a ...
متن کاملThe Application of Concurrent Engineering in the Installation of Foam Fire Extinguishing Piping System
Although the concept of concurrent engineering has been widely applied in the manufacturing industry, there is growing awareness and interest in the adoption of Concurrent Engineering (CE) in the Construction Industry because CE has the potential to make construction projects less fragmented, reduce project duration, improve project quality, reduce total project cost and increase project compet...
متن کاملWireless Sensor Network based Fire Monitoring and Extinguishing System in Real Time Environment
Wireless Sensor Network based Fire Monitoring and Extinguishing System in Real Time Environment P. N. Narendra Reddy, P. I. Basarkod, S. S. Manvi Department of Electronics and Communication Engineering REVA Institute of Technology and Management, Katigenahalli, Yelahanka, Bangalore, Karnataka, India560064 [email protected], [email protected], [email protected] -------------...
متن کاملIn-mine Evaluation of Underground Fire
The current s t a t e of the a r t of f i r e and smoke detect ion technology i s reviewed from the standpoint of s u i t a b i l i t y f o r use i n underground metal and nonmetal mines. Detection modes, f i r e signatures, and environmental considerat ions a r e included. Preliminary r e s u l t s of longterm, in-mine t e s t s a r e presented.
متن کاملStability analysis and selection of optimuim support system of large scale underground space-Case study
The Azad pumped storage power plant including the pumping and transformer cavern and surge tanks has been located in the Sanandaj-Sirjan formation with the alternation of slate and phyllite and meta sandstone.Due to the sensitivity and special use of these spaces, stability analysis and ensuring the safety of carven is very important.Nowadays, using the surface storage tanks is very costly; The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Science, Technology and Engineering Systems Journal
سال: 2017
ISSN: 2415-6698