Fire danger rating over Mediterranean Europe based on fire radiative power derived from Meteosat
نویسندگان
چکیده
منابع مشابه
Meteosat SEVIRI Fire Radiative Power (FRP) Products from the
4 Wooster, M.J., Roberts, G., Freeborn, P. H., Xu, W., Govaerts, Y., Beeby, R., 5 He, J. , A. Lattanzio, Fisher, D., and Mullen, R. 6 7 8 1 King’s College London, Environmental Monitoring and Modelling Research Group, 9 Department of Geography , Strand, London, WC2R 2LS, UK. 10 2 NERC National Centre for Earth Observation (NCEO), UK. 11 3 Geography and Environment, University of Southampton, Hi...
متن کاملBiomass burning emissions estimated with a global fire assimilation system based on observed fire radiative power
The Global Fire Assimilation System (GFASv1.0) calculates biomass burning emissions by assimilating Fire Radiative Power (FRP) observations from the MODIS instruments onboard the Terra and Aqua satellites. It corrects for gaps in the observations, which are mostly due to cloud cover, and filters spurious FRP observations of volcanoes, gas flares and other industrial activity. The combustion rat...
متن کاملA simple index for assessing fire danger rating
Fire danger rating systems are used to assess the potential for bushfire occurrence, fire spread and difficulty of fire suppression. Typically, fire danger rating systems combine meteorological information with estimates of the moisture content of the fuel to produce a fire danger index. Fire danger indices are used to declare fire bans and to schedule prescribed burns, among other applications...
متن کاملA sub-pixel-based calculation of fire radiative power from MODIS observations: 2. Sensitivity analysis and potential fire weather application
In most cases authors are permitted to post their version of the article (e.g. in Word or Tex form) to their personal website or institutional repository. Authors requiring further information regarding Elsevier's archiving and manuscript policies are encouraged to visit: a b s t r a c t a r t i c l e i n f o Keywords: Fire Wildfire Biomass burning MODIS Atmospheric correction Water vapor Emiss...
متن کاملSIL Rating Fire Protection Equipment
SIL's (Safety Integrity Levels) are used by IEC 61508:1998 [1] to characterise the required functional safety of computer control systems. For example, SIL 4, the highest rating is for fly by wire aircraft and weapons systems and track circuited train signalling systems while SIL 2 is typical of certain Programmable Logic Controllers (PLC). Fire control panels have not been SIL rated to date ev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Natural Hazards and Earth System Sciences
سال: 2018
ISSN: 1684-9981
DOI: 10.5194/nhess-18-515-2018