FILM –WISE CONDENSATION OF R1234yf AND R134a REFRIGERANTS ON FINNED TUBE WITH 32 FINS PER INCH

نویسندگان

چکیده

Researchers have been motivating by the global warming challenge to develop alternatives substances compounds that contribute this problem. The refrigerant R134a (HFC134a) has identified as one of most environmentally damaging gases. As a result, R1234yf employed in air conditioning systems substitute R134a. condensation heat transfer coefficient (HTC) refrigerants and was measured on smooth standard finned tubes study. tube is characterized 32 Fins per inch (FPI) 1 mm fin height. process investigated at 37°C 40°C condensing temperatures 16°C 28°C water inlet temperatures. Nusselt theory accurately predicted HTCs within mean absolute percentage deviation (MAPD) 5.3% for 4.7% R1234yf. wall sub-cooling increases, HTC decreases. With drop LMTD, overall rises. For tube, showed greater than In comparison enhancement ratio 78% 37 82% with 65% 81% 40 ° C, respectively. experimental data compared predictions two previous analytical models film tubes.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of a finned-tube evaporator optimized for different refrigerants and its effect on system efficiency

This paper presents a comparable evaluation of R600a (isobutane), R290 (propane), R134a, R22, R410A, and R32 in an optimized finned-tube evaporator, and analyzes the impact of evaporator effects on the system coefficient of performance (COP). The study relied on a detailed evaporator model derived from NIST’s EVAP-COND simulation package and used the ISHED1 scheme employing a non-Darwinian lear...

متن کامل

An Experimental Study On Condensation Of R134a In A Multi-Port Extruded Tube

In the present study, the local characteristics of pressure drop and heat transfer are investigated experimentally for the condensation of a pure refrigerant R134a in multi-port extruded tubes of 8 channels in 1.36mm hydraulic diameter and 19 channels in 0.80mm hydraulic diameter. The experimental data of frictional pressure drop (F.P.D.) and condensation heat transfer coefficient (H.T.C.) are ...

متن کامل

High Pressure Investigation of Refrigerants HFC245fa, R134a and R123

To increase the power efficiency of refrigeration and air conditioning machinery it would be advantageous to be able to run the compressors without any lubricant added to the refrigerant. Without any added lubricant in the refrigerant it would also be possible to simplify the whole refrigeration machinery by excluding all oil handling systems, and there would not any longer be any risk for oil ...

متن کامل

Oil Retention and Pressure Drop of R134a, R1234yf and R410A with POE 100 in Suction Lines

An experimental investigation of oil retention and pressure drop characteristics for R1234yf, R134a and R410A with POE 100 is presented, for horizontal and vertical suction lines of 10.2 mm internal diameter. Conditions of operation include a saturation temperature of 13 °C and a superheat of 15 °C, with the superficial vapor velocity and the Oil in Circulation Ratio (OCR) both varied in the ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: ???? ???? ?????? ????????

سال: 2022

ISSN: ['2305-6932', '2663-1970']

DOI: https://doi.org/10.31185/ejuow.vol10.iss2.303