Feedback and breakdown in parallel-plate chambers

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two New Parallel-plate Ionization Chambers for Electron Beam Dosimetry

-Two parallel-plate ionization chambers were projected, constructed and evauated for use in high energy electron beams. They were constructed using the two plastic materials recommended for clinical dosimetry protocols, i.e. acrylic and polystyrene. Both chambers have cylindrical shape with entrance windows in aluminized Mylar and they are open to the air. The acrylic chamber has a 2 mm air gap...

متن کامل

Resistive Plate Chambers in ATLAS

The ATLAS first level muon trigger is based, in the rapidity region ( v ( 5 1.05, on fast and finely segmented gaseous detectors, Resistive Plate Chambers (RPCs) . A prototype of a small scale RPC trigger tower has been assembled and tested. We present results on efficiency, time resolution, cluster size and collected charge. The detectors, filled with a non-flammable and environment-safe gas m...

متن کامل

Induced signals in resistive plate chambers

We derive theorems for induced signals on electrodes embedded in a medium with a position and frequencydependent permittivity eð~x; sÞ and conductivity sð~x; sÞ that are connected with arbitrary discrete elements. The problem is treated using the quasi-static approximation of Maxwell’s equations for weakly conducting media. The induced signals can be derived by time-dependent weighting fields a...

متن کامل

Space Charge Effects in Resistive Plate Chambers

We extend an existing one dimensional simulation model for avalanche mode RPCs by the inclusion of diffusion and space charge effects. We investigate the influence of space charge on charge spectra, signal rise time, time resolution and charge-to-time correlation. We present a 1.5-dimensional model, which allows fast simulation of events and a two dimensional model that is slower but allows to ...

متن کامل

Observation of light from resistive plate chambers

Electrically induced signals and light emissions from Restrictive Plate Chamber (RPC) are simultaneously measured using a glass RPC with transparent high-voltage planes, operating in the streamer mode. With one exception, good correspondence is seen in between the electrical and optical signals in every aspect: signal shapes, pulse heights, timing and afterpulses. The one exception is a possibl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

سال: 1991

ISSN: 0168-9002

DOI: 10.1016/0168-9002(91)90522-r