Fast Monte Carlo-Based Inverse Planning for Prostate Brachytherapy by Using Deep Learning
نویسندگان
چکیده
Inverse planning is an essential tool for optimizing the delivered radiation dose on low-dose-rate (LDR) prostate brachytherapy. Clinical inverse systems use TG-43 computation formalism in order to perform a fast optimization. However, this method approximation that often leads overestimation, resulting suboptimal plans. Alternatively, Monte Carlo simulation (MCS) can be used obtain accurate distribution, but considerably increasing estimation time. We propose LDR brachytherapy uses deep convolutional neural network (DCNN) trained graphics processing unit (GPU)-based MCS generated database estimate distribution and organs at risk. Segmentations of seeds’ positions are given as DCNN input. The mean percent error test set was −1.19±0.94% within prostate. dosimetric parameters each organ every configuration optimization loop. final DCNN-based plans were good agreement compared same recalculated with full MCS. proposed based capable reach equivalent level accuracy runtime less than 1 min using conventional GPU card.
منابع مشابه
CT-Based Brachytherapy Treatment Planning using Monte Carlo Simulation Aided by an Interface Software
Introduction: In brachytherapy, radioactive sources are placed close to the tumor, therefore, small changes in their positions can cause large changes in the dose distribution. This emphasizes the need for computerized treatment planning. The usual method for treatment planning of cervix brachytherapy uses conventional radiographs in the Manchester system. Nowadays, because of their advantages ...
متن کاملct-based brachytherapy treatment planning using monte carlo simulation aided by an interface software
introduction: in brachytherapy, radioactive sources are placed close to the tumor, therefore, small changes in their positions can cause large changes in the dose distribution. this emphasizes the need for computerized treatment planning. the usual method for treatment planning of cervix brachytherapy uses conventional radiographs in the manchester system. nowadays, because of their advantages ...
متن کاملMonte Carlo-based inverse treatment planning.
A Monte Carlo based inverse treatment planning system (MCI) has been developed which combines arguably the most accurate dose calculation method (Monte Carlo particle transport) with a 'guaranteed' optimization method (simulated annealing). A distribution of photons is specified in the tumour volume; they are transported using an adjoint calculation method to outside the patient surface to buil...
متن کاملAn Approach in Radiation Therapy Treatment Planning: A Fast, GPU-Based Monte Carlo Method
Introduction: An accurate and fast radiation dose calculation is essential for successful radiation radiotherapy. The aim of this study was to implement a new graphic processing unit (GPU) based radiation therapy treatment planning for accurate and fast dose calculation in radiotherapy centers. Materials and Methods: A program was written for parallel runnin...
متن کاملAccelerated Monte Carlo based dose calculations for brachytherapy planning using correlated sampling.
Current brachytherapy dose calculations ignore applicator attenuation and tissue heterogeneities, assuming isolated sources embedded in unbounded medium. Conventional Monte Carlo (MC) dose calculations, while accurate, are too slow for practical treatment planning. This study evaluates the efficacy of correlated sampling in reducing the variance of MC photon transport simulation in typical brac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE transactions on radiation and plasma medical sciences
سال: 2022
ISSN: ['2469-7303', '2469-7311']
DOI: https://doi.org/10.1109/trpms.2021.3060191