FABRICATION OF POLYMER BASED SCHOTTKY DIODE USING PANI/AG NANO COMPOSITE
نویسندگان
چکیده
منابع مشابه
Schottky Diode Graphene Based Sensors
In this paper, we aim to demonstrate a novel scheme for integration of nanostructured semiconductor Graphene Oxide (GO) shottky diodes on flexible substrate for a wide range of sensing applications. The platform introduces a novel flexible GO/Pt/n-Si and GO/Pt/SiN composite structures which provides excellent optical and electrical properties, while maintaining an acceptable mechanical, biocomp...
متن کاملFormation of Composite Polymer ‘diode-like’ Membranes
The method of formation of the composite polymer ‘diode-like’ membranes, that possess asymmetry of conductivity in electrolyte solution – a rectification effect similar to that of a p-n junction in semiconductors, is described. To prepare the ‘diodelike’ membranes, a thin polymer layer synthesized in plasma was deposited on the one side of a poly(ethylene terephthalate) track membrane. Study of...
متن کاملConverter Using Silicon Carbide Schottky Diode
Silicon carbide (SiC) is the perfect cross between silicon and diamond. The crystal lattice of SiC is identical to silicon and diamond, but, exactly half the lattice sites are occupied by silicon atoms and half by carbon atoms. Like-diamond siC has electronic properties superior to silicon, but, unlike diamond it is also manufacturable. The thermal leakage current (dark current) in SiC is sixte...
متن کاملCopper phthalocyanine based Schottky diode solar cells
Copper phthalocyanine (CuPc)/Aluminum (Al) Schottky diode solar cells were studied. The thickness of the CuPc layer was varied from 15 nm to 140 nm. Short circuit current densities (Jsc) increased with thickness from 0.042 mA/cm at 15 nm to 0.124 mA/cm at 120 nm reaching saturation at that level. Open circuit voltages (Voc) increased from 220 mV at 15 nm to 907 mV at 140 nm. Analysis of the cur...
متن کاملFabrication of PGS/CaTiO3 Nano-Composite for Biomedical Application
Biodegradable elastomeric materials are gaining extensive attention in the field of soft tissue engineering. Poly (glycerol sebacate) (PGS) is a novel biocompatible elastomer in this scope. However this polymer has poor mechanical properties especially when the molar ratio of glycerol is higher than sebacic acid. Calcium Titanate (CaTiO3) is a biocompatible ceramic with some degr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Research in Engineering and Technology
سال: 2014
ISSN: 2321-7308,2319-1163
DOI: 10.15623/ijret.2014.0319039