Experimental Investigation and Numerical Simulation of Corrugated Steel Plate Shear Wall Considering the Gravity Load
نویسندگان
چکیده
The corrugated steel plate shear wall (CSPSW) has high strength, ductility, and energy dissipation capacity can be used as the lateral force-resisting system of multi-story high-rise buildings. vertical load transmitted by upper floor frame columns may inevitably act on wall. However, influence gravity performance is not considered in most studies. To investigate behavior walls considering actual load, four scaled SPSWs under loading were tested. specimens’ failure mode, envelope curves, hysteretic curves analyzed. A numerical simulation model was established based validation experimental test SPSWs. results showed that hysteresis consistent with those results. Finally, parametric analysis conducted different types infill plates, height-to-thickness ratio, loads.
منابع مشابه
Experimental and Numerical Study of Perforated Steel Plate Shear Panels
Thin perforated Steel Plate Shear (SPS) Walls are among the most common types of energy dissipating systems. The applied holes reduce the shear strength of the plate and allow to decrease the profile size of the members at the boundary of the panel when these systems are used in the typical design of structures. On the other hand, the different fracture locations of these panels are visible whe...
متن کاملComparison of plasticity and stiffness of steel shear walls with composite steel plate shear wall
The steel shear wall and composite steel plate shear wall is introduced in recent three decade and is considered and is spread rapidly. Composite steel plate shear wall which is made of a layer of thin steel sheet with coating of reinforced concrete in one or both sides of steel palate is considered a third generation of resistance shear walls against lateral loads that in addition to increasin...
متن کاملExperimental Investigation of Light-Gauge Steel Plate Shear Walls
This paper describes the prototype design, specimen design, experimental setup, and experimental results of three light-gauge steel plate shear wall concepts. Prototype light-gauge steel plate shear walls are designed as seismic retrofits for a hospital structure in an area of high seismicity, and emphasis is placed on minimizing their impact on the existing framing. Three single-story test spe...
متن کاملExperimental Investigation on Cold-formed Steel Wall Plate System
A series of tests on cold-formed steel (CFS) wall plate system subjected to uplift force at the mid span of the wall plate is presented. The aim of the study was to study the behaviour and identify the modes of failure of CFS wall plate system. Two parameters were considered in these studies: 1) different dimension of U-bracket at the supports and 2) different sizes of lipped Cchannel. The lipp...
متن کاملAn Experimental Study on the Shear Hysteresis and Energy Dissipation of the Steel Frame with a Trapezoidal-Corrugated Steel Plate
The steel frame reinforced with steel shear wall is a lateral load resisting system and has higher strength and shear performance than the concrete shear wall system. Especially, using corrugated steel plates in these shear wall systems improves out-of-plane stiffness and flexibility in the deformation along the corrugation. In this paper, a cyclic loading test of this steel frame reinforced wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Buildings
سال: 2023
ISSN: ['2075-5309']
DOI: https://doi.org/10.3390/buildings13020346