In this work we analyze numerically different design configurations to be used in a R1234yf DMS cycle coupled with water source, transcritical CO2 heat pump for heating applications the building sector. Specifically, study temperature range proposed by European standard inlet/outlet temperatures of: 30 °C/35 °C, 40 °C/45 47 °C/55 °C and 55 °C/65 °C. Moreover, 25 °C/30 is also analyzed which expected indoor swimming pool applications. A inlet of 10 at evaporator was considered all cases. Results show that depending on coupling strategy between pump, optimal COP values obtained can vary up 30% whereas operating pressure 8%. configuration based splitting flow heated into condenser gas cooler system IHX best option ranges studied. The improvement maximum 5% (for applications) 25% space °C) when compared base considered. When not considered, basic without found option.
منابع مشابه
Performance of a Transcritical CO2 Heat Pump for Simultaneous Water Cooling and Heating
This paper presents the experimental as well as the simulated performance studies on the transcritical CO2 heat pumps for simultaneous water cooling and heating; effects of water mass flow rates and water inlet temperatures of both evaporator and gas cooler on the cooling and heating capacities, system COP and water outlets temperatures are investigated. Study shows that both the water mass flo...
متن کاملField Evaluation for Air-source Transcritical CO2 Heat Pump Water Heater with Optimal Pressure Control
Several optimal discharge pressure correlations for transcritical CO2 heat pump in literature have been discussed in this paper. Most of them are related to the ambient temperature, the evaporation temperature and the gas cooler outlet temperature. A revised optimal discharge pressure model as the function of ambient temperature and water outlet temperature is developed based on earlier experim...
متن کاملOptimization of a transcritical CO2 heat pump cycle for simultaneous cooling and heating applications
Energetic and exergetic analyses as well as optimization studies of a transcritical carbon dioxide heat pump system are presented in this article. A computer code has been developed to obtain sub-critical and super-critical thermodynamic and transport properties of carbon dioxide. Estimates for irreversibilities of individual components of the system lead to possible measures for performance im...
متن کاملthe use of appropriate madm model for ranking the vendors of mci equipments using fuzzy approach
abstract nowadays, the science of decision making has been paid to more attention due to the complexity of the problems of suppliers selection. as known, one of the efficient tools in economic and human resources development is the extension of communication networks in developing countries. so, the proper selection of suppliers of tc equipments is of concern very much. in this study, a ...
15 صفحه اولEnergy Optimization for Transcritical CO2 Heat Pumps for Combined Heating and Cooling and Thermal Storage Applications
A transcritical heat pump (THP) cycle using carbon dioxide (CO2) as the refrigerant is known to feature an excellent coefficient of performance (COP) as a thermodynamic system. Using this feature, we are designing and building a system that combines a water-to-water CO2 heat pump with both hot and cold thermal storages know as Thermal Battery (TB) (Blarke, 2012). Smart and effective use of inte...