Evaluation of antioxidant capacity in different food matrices through differential pulse voltammetry and its correlation with spectrophotometric methods

نویسندگان

چکیده

Abstract Differential pulse voltammetry (DPV) and spectrophotometric methods were used to evaluate the antioxidant capacity (AC) in strawberry orange juice, soluble coffee, rosemary extract, red wine, sparkling white wine. The AC through showed following trend solid foods, coffee > wine juice liquid samples. Charge measurements by DPV, presented equivalent units of Trolox gallic acid, same samples; however, for samples, extract was greater than that coffee. charge expressed a high, positive, significant correlation ( p < 0.001) with total phenols (0.7919), FRAP (0.8875), ABTS (0.8366). proposed electrochemical technique proves be fast, reliable, environmentally friendly alternative or complement food, which is not affected turbidity color Graphical abstract

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

comparative dna interaction studies of antiviral drug, zidovudine and its complex using different instrumental methods

هدف از این مطالعه بررسی امکان استفاده از داروهای شناخته شده در درمان سایر بیماریها به عنوان داروهای ضد سرطان است. همچنین با استفاده از این داروها در ساختمان کمپلکس فلز می توان شاخص های دارویی بدست آمده را بررسی نمود. داروی ضد ویروس ایدز(hiv)به نام زیدوودین(azt)انتخاب و.کمپلکس.محلول.در.آب[pt(azt)2]cl2سنتزو به روشهای مختلف فیزیکی و شیمیایی شناسایی گردید. بر هم کنش مقایسه ای این دارو و کمپلکس پلا...

15 صفحه اول

Determination of polyphenols content and antioxidant activity of some red wines by differential pulse voltammetry, HPLC and spectrophotometric methods

0308-8146/$ see front matter 2010 Published by doi:10.1016/j.foodchem.2010.07.047 * Corresponding author. Tel.: +385 31 224 325; fax E-mail address: [email protected] (M. Šeruga). Red wines produced in three different wine growing regions of Croatia were analysed for total polyphenols (TP) content, concentration of individual polyphenols and antioxidant activity (AA). TP content was measured by ...

متن کامل

Determination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods

In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containin...

متن کامل

Determination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods

In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containin...

متن کامل

the effect of functional/notional approach on the proficiency level of efl learners and its evaluation through functional test

in fact, this study focused on the following questions: 1. is there any difference between the effect of functional/notional approach and the structural approaches to language teaching on the proficiency test of efl learners? 2. can a rather innovative language test referred to as "functional test" ge devised so so to measure the proficiency test of efl learners, and thus be as much reliable an...