EP-2055 Impact of patient-specific MRI distortion correction for stereotactic cranial target definition
نویسندگان
چکیده
منابع مشابه
An image correction protocol to reduce distortion for 3-T stereotactic MRI.
BACKGROUND Image distortion limits application of direct 3-T magnetic resonance imaging for stereotactic functional neurosurgery. OBJECTIVE To test the application of a method to correct and curtail image distortion of 3-T magnetic resonance images. METHODS We used a phantom head model mounted on a platform with the dimensions and features of a stereotactic frame. The phantom was scanned wi...
متن کاملthe impact of skopos on syntactic features of the target text
the present study is an experimental case study which investigates the impacts, if any, of skopos on syntactic features of the target text. two test groups each consisting of 10 ma students translated a set of sentences selected from advertising texts in the operative and informative mode. the resulting target texts were then statistically analyzed in terms of the number of words, phrases, si...
15 صفحه اولComparison of EPI Distortion Correction Methods in Diffusion Tensor MRI
Introduction Diffusion weighted images (DWIs) used for Diffusion Tensor (DT) calculation are commonly acquired with Echo-planar imaging (EPI). Unfortunately, EPI is very sensitive to magnetic field (B0 ) inhomogeneities, which result in local geometric distortions in regions close to air-tissue interfaces. These distortions degrade the anatomical accuracy of DT-MRI maps and potentially increase...
متن کاملCorrection and Quantification of Geometric Distortion in MRI
stract--Magnetic Resonance (MR) images can have sig.qcant geometric distortion due to unintended errors in e magnetic fields used in the scanners. We present a w method to quantify the extent of the misregistration used by magnetic field inhomogeneities in MR images to bpixel accuracy. This method does not require an ex:nal standard such as Computed Tomography (CT) nor es it require that the ge...
متن کاملDistortion Correction Method for Single Echo DTI at 7T MRI using Non-distortion and Distortion Dimension Combined PSF Mapping Technique
S-H. Oh, J-Y. Chung, S-Y. Park, D. Kim, M-H. In, M. Zaitsev, O. Speck, Y-B. Kim, and Z-H. Cho Neuroscience Research Institute, Gachon University of Medicine and Science, Incheon, Incheon, Korea, Republic of, Department of Electrical Engineering, Korea Advance Institute of Science and Technology, Daejeon, Daejeon, Korea, Republic of, Department of Biomedical Magnetic Resonance, Institute for Exp...
متن کاملذخیره در منابع من