EP-1739: Phantom capable of testing Smart Deviceless4D – four-dimensional CT (4DCT) – system development

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Four-dimensional computed tomography (4D CT)--concepts and preliminary development.

Four-dimensional computed tomography (4D CT) is a dynamic volume imaging system of moving organs with an image quality comparable to that of conventional CT. 4D CT will be realized by several technical breakthroughs for dynamic cone-beam CT: (1) a large-area two-dimensional (2D) detector; (2) high-speed data transfer system; (3) reconstruction algorithms; (4) ultra-high-speed reconstruction com...

متن کامل

Development of a minipig physical phantom from CT data

Quantification of pathological progression of radiation-induced injury is essential in development of treatment methods, and a proper animal model is necessary for relevant radiological and medical studies. A minipig is a current animal model selected because of its similarities to humans in anatomy and pathology. In the present study, a minipig physical phantom was developed using computed tom...

متن کامل

Collision detection by four-dimensional intersection testing

The collision detection problem is easily stated: \Given two objects and desired motions, decide whether the objects will come into collision over a given time span". The solution of this problem is useful, both in robotics and other problem domains. We describe a method for solving collision detection that involves transforming the problem into an intersection detection problem over space-time...

متن کامل

Design and Fabrication of a Four-Dimensional Respiratory Phantom for Studying Tumor Movement in Radiotherapy with Magnetic Resonance Imaging

Introduction: In radiation therapy, determining the location of the tumor accurately during irradiation is one of the most important requirements. However, lung tumors are not fixed in a single location and move during irradiation due to respiratory motion. Due to limitations in assessing such movements, using a lung phantom can be useful and operational for their fast, easy an...

متن کامل

Design and Fabrication Process of MTF Phantom CT Scan

Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiotherapy and Oncology

سال: 2018

ISSN: 0167-8140

DOI: 10.1016/s0167-8140(18)32048-6