Diode calibration for dose determination in total body irradiation

Background: Total Body Irradiation (TBI) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under TBI treatment. Diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. The aim of this study was to describe the measurements made to calib...

متن کامل

Evaluation of Deformable Image Registration (DIR) Methods for Dose Accumulation in Nasopharyngeal Cancer Patients during Radiotherapy

Introduction Deformable image registration (DIR) is used to modify structures according to anatomical changes for observing the dosimetric effect. In this study, megavoltage computed tomography (MVCT) images were used to generate cumulative doses for nasopharyngeal cancer (NPC) patients by various DIR methods. The performance of the multiple DIR methods was analysed, and the impact of dose accu...

متن کامل

Evaluation of deformable image registration in HDR gynecological brachytherapy

Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...

متن کامل

diode calibration for dose determination in total body irradiation

background: total body irradiation (tbi) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under tbi treatment. diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. the aim of this study was to describe the measurements made to calibrate diod...

متن کامل

Comparing rigid and deformable dose registration for high dose thoracic re-irradiation.

For patients with locally-recurrent lung cancer, high dose thoracic re-irradiation can prolong survival. Deformable image registration improves the accuracy with which initial treatments are accounted for compared to rigid image registration. Using deformable image registration will improve correlative toxicity data, and may reduce toxicity for selected patients undergoing re-irradiation.

متن کامل