Enhanced turbine monitoring using emissions measurements and data reconciliation
نویسندگان
چکیده
منابع مشابه
Improving Data-based Wind Turbine Using Measured Data Foggy Method
The purpose of this paper is to improve the modeling of the data-driven wind turbine system that receives data from noise signals. Most of the data on industrial systems is noisely and data noise is inevitable and natural. The method and idea proposed in this paper, Data Fogging, significantly reduce the impact of noise on data-driven wind turbine system modeling, which is the basis of this met...
متن کاملA Wavelet Enhanced Integral Approach to Linear Dynamic Data Reconciliation
An integral approach for dynamic data reconciliation that combines a direct numerical integration via Simpson’s rule and data smoothing via discrete wavelet decomposition is presented. By simple numerical integration, the differential-algebraic equations governing the material balances are transformed into algebraic constraints to formulate the reconciliation problem. The frequency responses an...
متن کاملMissing Data Treatment Using Iterative Pca and Data Reconciliation
Two methods, one based on Iterative Principal Components Analysis(IPCA) and the other based on Data Reconciliation have been developed for estimating a model from a data matrix containing missing data. These algorithms are iterative in nature and analogous to the method based on PCA for treating missing data. The methods incorporate information about the measurement errors to develop the models...
متن کاملAir Emissions Measurements in Environmental Monitoring of IPPC Plants
This paper describes some air emissions measurements items coming from the application of the authorization decrees licensing IPPC Plants in Italy at national level in order to respect authorized monitoring and control procedures. New technical situations are analyzed as they occur in plants operation, after release of IPPC operational licensees, as in these Plants where pollution is now under ...
متن کاملObservability-Enhanced PMU Placement Considering Conventional Measurements and Contingencies
Phasor Measurement Units (PMUs) are in growing attention in recent power systems because of their paramount abilities in state estimation. PMUs are placed in existing power systems where there are already installed conventional measurements, which can be helpful if they are considered in PMU optimal placement. In this paper, a method is proposed for optimal placement of PMUs incorporating conve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied Energy
سال: 2016
ISSN: 0306-2619