Enhanced dynamic wedge factors at off‐axis points in asymmetric fields

Several recent reports have described methods for calculating enhanced dynamic wedge factors (EDWFs). Many of these reports use the monitor-unit (MU) fraction method to predict EDWFs as a function of field size. Although simple in approach, MU fraction methods do not produce accurate EDWFs in large or asymmetric fields. A recently described technique, based on the MU fraction method works well ...

متن کامل

A spreadsheet solution for off‐axis, noncentral enhanced dynamic wedge factors

Enhanced dynamic wedges can be very useful in increasing radiation therapy treatment efficiency. A drawback to their use is finding a factor analogous to a conventional wedge factor to calculate the dose to a point in a dynamically wedged field. A formalism has previously been published [J. Gibbons, Med. Phys. 25, 1411-1418 (1998)] to determine this factor at the central point of a dynamically ...

متن کامل

Dosimetric evaluation of a treatment planning system using pencil beam convolution algorithm for enhanced dynamic wedges with symmetric and asymmetric fields

Background: The dosimetric performance of Eclipse 6.5 three dimensional treatment planning system (3DTPS) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of American Association for Physicists in Medicine Task Group 53. Materials and Methods: The calculations were performed by the 3DTPS for symmetric as well as asymmetric fields for standar...

متن کامل

Elimination of field size dependence of enhanced dynamic wedge factors.

Enhanced dynamic wedge factors (EDWF) are characterized by a strong field size dependence. In contrast to physical wedge factors, the EDWF decrease as the field size is increased: for 6 MV 60 degrees wedge, the EDWF decreases by 50% when the field size is increased from 4 x 4 cm2 to 20 x 20 cm2. A method that eliminates the field size dependence of EDWF was developed and investigated in this wo...

متن کامل

Optimum reckoning of contra lateral breast dose using physical wedge and enhanced dynamic wedge in radiotherapy treatment planning system

Background: It was intended to investigate the effect of physical wedge (PW) and enhanced dynamic wedges (EDW) on contralateral breast dose during primary breast irradiation in radiotherapy treatment, using high energy photon beams. Materials and Methods: The Varian’s Clinac dual mode linear accelerator model 2100 C/D and Siemen’s Primus accelerators were used for radiation doses wi...

متن کامل