When earthquakes occur, energy released by the earthquake gets induced into the structure as ground motion and this energy has to be dissipated for safety reasons. To release seismic energy, the structure should damage in such a way that on one hand, collapse of structure should not occur and on the other hand, after the earthquake, damage should be economically feasible to repair. To avoid the...
متن کاملExperimental Evaluation of Performance Criteria for Reinforced Concrete Beams under Cyclic Loading
To assess the performance criteria of the reinforced-concrete, five-storey residential buildings common in Iran, an experimental study in the structural laboratory of the University of Tehran has been conducted. The test program includes cyclic and monotonic load tests of six beams that represent three-to-five storey buildings with rigid frame structures. Using definitions given in FEMA-356 a...
متن کاملExperimental Evaluation of Performance Criteria for Reinforced Concrete Beams under Cyclic Loading
To assess the performance criteria of the reinforced-concrete, five-storey residential buildings common in Iran, an 
experimental study in the structural laboratory of the University of Tehran has been conducted. The test program includes cyclic and monotonic load tests of six beams that represent three-to-five storey buildings with rigid frame structures. Using definitions given in FEMA-356...
متن کاملDuctility of Prestressed and Partially Prestressed Concrete Beam Sections
D analyses of structures responding elastically to ground motions recorded during severe earthquakes have shown that the theoretical response inertia loads are generally significantly greater than the static design lateral loads recommended by codes. Hence, structures designed for the lateral earthquake loads recommended by codes can only survive severe earthquakes if they have sufficient ducti...
متن کاملReinforced Concrete Bridge Piers Subjected to Reversed Cyclic Loading
Sixteen large-scale reinforced concrete specimens without web reinforcements were tested to study the behavior of typical bridge piers subjected to deflection reversals that were large enough to cause extensive yielding of the longitudinal reinforcement. The different parameters considered included shear spanto-depth ratio, percentage of longitudinal reinforcement, frequency of the applied load...