Electric field simulations of high voltage DC extruded cable systems
نویسندگان
چکیده
منابع مشابه
High voltage gain DC-DC resonant converter
In this paper, a DC-DC resonant converter with high voltage gain and small size is studied. To reduce the size and weight of this converter, the operating frequency should be as high as possible. In this research, the frequency changes from 120 to 200 kHz. Due to the high operating frequency, it is necessary to reduce the switching losses using soft switching methods. Resonant converters are su...
متن کاملHigh voltage gain DC-DC resonant converter
In this paper, a DC-DC resonant converter with high voltage gain and small size is studied. To reduce the size and weight of this converter, the operating frequency should be as high as possible. In this research, the frequency changes from 120 to 200 kHz. Due to the high operating frequency, it is necessary to reduce the switching losses using soft switching methods. Resonant converters are su...
متن کاملElectric Field Simulations and Analysis for High Voltage High Power Medium Frequency Transformer
The electronic power transformer (EPT) raises concerns for its notable size and volume reduction compared with traditional line frequency transformers. Medium frequency transformers (MFTs) are important components in high voltage and high power energy conversion systems such as EPTs. High voltage and high power make the reliable insulation design of MFT more difficult. In this paper, the influe...
متن کاملhigh voltage gain dc-dc resonant converter
in this paper, a dc-dc resonant converter with high voltage gain and small size is studied. to reduce the size and weight of this converter, the operating frequency should be as high as possible. in this research, the frequency changes from 120 to 200 khz. due to the high operating frequency, it is necessary to reduce the switching losses using soft switching methods. resonant converters are su...
متن کاملElectric Field Modelling of Non-Ceramic High Voltage Insulators
Electric field calculations are not common practice in the design and development of non-ceramic insulators for high voltage transmission applications. This paper applies a three-dimensional (3D) electric field analysis program to calculate the field distribution at the live-end of 275kV and 330 kV non-ceramic insulators used in the Queensland transmission system. At these voltages, fields can ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Electrical Insulation Magazine
سال: 2017
ISSN: 0883-7554
DOI: 10.1109/mei.2017.7956628