ELASTO-PLASTIC HYSTERETIC BEHAVIOR OF PRESTRESSED CONCRETE BEAMS

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hysteretic Behavior of Prestressed Concrete Bridge Pier with Fiber Model

The hysteretic behavior and seismic characteristics of the prestressed concrete bridge pier were researched. The effects of the prestressed tendon ratio, the longitudinal reinforcement ratio, and the stirrup reinforcement ratio on the hysteretic behavior and seismic characteristics of the prestressed concrete bridge pier have been obtained with the fiber model analysis method. The analysis show...

متن کامل

Behavior of Prestressed Concrete Beams with CFRP Strands

................................................................................................................................. i Dedication........................................................................................................................... iii Acknowledgements............................................................................................................. i...

متن کامل

Hysteretic Behavior of Conventionally Reinforced Concrete Coupling Beams in Reinforced Concrete Coupled Shear Wall

This paper presents the experimental results of four full-scale coupling beams in which only horizontal reinforcements are placed, without diagonal reinforcements, with the aim to develop reinforcement details for coupling beams used in connecting side walls in a wall-slab structural system. Each coupling beam specimen was designed according to the deep-beam design procedure that does not use d...

متن کامل

SERVICEABILITY OF CONCRETE BEAMS PRESTRESSED BY CARBON FffiRE REINFORCED PLASTIC .RODS

This paper describes an experimental program undertaken at the University of Manitoba to study the serviceability of concrete beams prestressed by carbon fibre reinforced plastic (CFRP) rods. The experimental program consisted of eight concrete beams prestressed by CFRP rods and two concrete beams prestressed by conventional steel strands. The beams were tested using two static concentrated loa...

متن کامل

Non - linear analysis of externally prestressed concrete beams

In an external prestressing system, there is no strain compatibility between the cable and the concrete at every cross-section, the increment of cable strain must be evaluated by taking into account the whole structure, rather than performing the calculation at each section, independently. In this study, a method for the calculation of cable strain, which is based on the deformation compatibili...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)

سال: 1990

ISSN: 0910-8025,2433-0000

DOI: 10.3130/aijsx.410.0_63