Effects of Nebulizer Position, Gas Flow, and CPAP on Aerosol Bronchodilator Delivery: An In Vitro Study
نویسندگان
چکیده
منابع مشابه
Effects of Nebulizer Position, Gas Flow, and CPAP on Aerosol Bronchodilator Delivery: An In Vitro Study.
BACKGROUND The aim of this study was to investigate the effects of different delivery circuit configurations, nebulizer positions, CPAP levels, and gas flow on the amount of aerosol bronchodilator delivered during simulated spontaneous breathing in an in vitro model. METHODS A pneumatic lung simulator was connected to 5 different circuits for aerosol delivery, 2 delivering CPAP through a high...
متن کاملComparison of HFNC, bubble CPAP and SiPAP on aerosol delivery in neonates: An in-vitro study.
UNLABELLED Aerosol drug delivery via high flow nasal cannula (HFNC), bubble continuous positive airway pressure (CPAP), and synchronized inspiratory positive airway pressure (SiPAP) has not been quantified in spontaneously breathing premature infants. OBJECTIVES The purpose of this study was to compare aerosol delivery via HFNC, bubble CPAP, and SiPAP in a model of a simulated spontaneously b...
متن کاملEffects of ventilator settings, nebulizer and exhalation port position on albuterol delivery during non-invasive ventilation: an in-vitro study
BACKGROUND Few studies have investigated the factors affecting aerosol delivery during non-invasive ventilation (NIV). Our aim was to investigate, using a bench-top model, the effect of different ventilator settings and positions of the exhalation port and nebulizer on the amount of albuterol delivered to a lung simulator. METHODS A lung model simulating spontaneous breathing was connected to...
متن کاملthe effects of changing roughness on the flow structure in the bends
flow in natural river bends is a complex and turbulent phenomenon which affects the scour and sedimentations and causes an irregular bed topography on the bed. for the reason, the flow hydralics and the parameters which affect the flow to be studied and understand. in this study the effect of bed and wall roughness using the software fluent discussed in a sharp 90-degree flume bend with 40.3cm ...
In vitro evaluation of radio-labeled aerosol delivery via a variable-flow infant CPAP system.
BACKGROUND Nasal CPAP is widely used in neonatal ICUs. Aerosolized medications such as inhaled steroids and β agonists are commonly administered in-line through nasal CPAP, especially to infants with bronchopulmonary dysplasia. We hypothesized that aerosol delivery to the lungs via variable-flow nasal CPAP in an in vitro model would be unreliable, and that the delivery would depend on the posit...