Effectiveness of protective patient equipment for CT: an anthropomorphic phantom study
نویسندگان
چکیده
منابع مشابه
A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom
Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...
متن کاملa simulation study on patient setup errors in external beam radiotherapy using an anthropomorphic 4d phantom
introduction patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. in this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4d) xcat anthropomorphic phantom. materials and methods to access 4d modeling of motion...
متن کاملAn anthropomorphic beating heart phantom for cardiac X‐ray CT imaging evaluation
The current work describes an anthropomorphic beating heart phantom constructed as a tool for the assessment of technological advances in cardiac x-ray computed tomography (CT). The phantom is comprised of a thorax, a compressor system, an ECG system, a beating heart with tortuous coronary arteries, and the option to add or remove pathologies such as aberrant beats, stents, and plaques. Initial...
متن کاملEvaluation of a 4D Cone-Beam CT Reconstruction Approach Using an Anthropomorphic Phantom
We have previously developed image-guided navigation systems for thoracic abdominal interventions utilizing a three dimensional (3D) Cone-Beam CT (CBCT) image acquired at breath-hold. These systems required the physician to perform the intervention in a gated manner, with actions performed at the same respiratory phase in which the CBCT image was acquired. This approach is not always applicable...
متن کاملRadiation dose evaluation in tomosynthesis and C-arm cone-beam CT examinations with an anthropomorphic phantom.
PURPOSE The objective of this study was to evaluate organ dose and the effective dose to patients undergoing tomosynthesis (TS) and C-arm cone-beam computed tomography (CBCT) examinations and to compare the doses to those in multidetector CT (MDCT) scans. METHODS Patient doses were measured with small sized silicon-photodiode dosimeters, 48 in number, which were implanted at various tissue an...