Effective Gain and Ion Back Flow study of triple and quadruple GEM detector
نویسندگان
چکیده
Abstract Gas electron Multipliers (GEM) are a new generation of gaseous avalanche devices in the Micro Pattern Gaseous Detector (MPGD) category. GEMs widely used both nuclear and high energy experiments as well medical science. Several parameters define performance these types under various experimental conditions. This article focuses on study effective gain Ion Back Flow (IBF) triple quadruple GEM detectors. Effective IBF two most important determining
منابع مشابه
Comparison of quadruple and triple Furazolidone containing
Background: The effectiveness of classic standard triple therapy regimen of helicobacter pylori (H. pylori) eradication has decreased to unacceptably low levels, largely related to development of resistance to metronidazole and clarithromycin. Thus successful eradication of H. pylori infections remains challenging. Therefore alternative treatments with superior effectiveness and safety should...
متن کاملTest and characterization of a new Triple-GEM detector
In my thesis project, I provide a description of the entire process of materials preparation, assembly, testing, and characterization of several triple-GEM (Gas-Electron Multiplier) prototype detectors. GEM detectors represent one of the latest developments in a new style of gaseous particle detectors. They have become well-known and widely used. Improvements in foil production are important fo...
متن کاملSingle Electron Detection in Quadruple-GEM Detector with Pad Readout
Using a system of four GEMs operating in tandem and coupled to pad readout, we have demonstrated the detection of single electrons in ethane at 1 bar. The paper presents measurements of single electron pulse height distributions, total gas gain measurement and calculation, pad-to-pad cross-talk, quenching capability, high rate capability, charging effects, etc. We describe the overall operation...
متن کاملthe study of practical and theoretical foundation of credit risk and its coverage
پس از بررسی هر کدام از فاکتورهای نوع صنعت, نوع ضمانت نامه, نرخ بهره , نرخ تورم, ریسک اعتباری کشورها, کارمزد, ریکاوری, gdp, پوشش و وثیقه بر ریسک اعتباری صندوق ضمانت صادرات ایران مشخص گردید که همه فاکتورها به استثنای ریسک اعتباری کشورها و کارمزد بقیه فاکتورها رابطه معناداری با ریسک اعتباری دارند در ضمن نرخ بهره , نرخ تورم, ریکاوری, و نوع صنعت و ریسک کشورها اثر عکس روی ریسک اعتباری داردو پوشش, وثی...
15 صفحه اول0 A triple GEM detector with two dimensional readout
This is a reduced version for hep-ex, from which the large photographs have been omitted to keep it small in size.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Instrumentation
سال: 2022
ISSN: ['1748-0221']
DOI: https://doi.org/10.1088/1748-0221/17/12/t12004