Early distal femoral endoprosthetic survival: cemented stems versus the Compress® implant

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distal femoral physeal growth arrest secondary to a cemented proximal femoral endoprosthetic replacement.

We report a case of spontaneous physeal growth arrest of the distal femur in a nine-year-old child with Ewing's sarcoma of the proximal femur treated with chemotherapy and endoprosthetic replacement. Owing to the extent of disuse osteoporosis at the time of surgery, the entire intramedullary canal up to the distal femoral physis was filled with cement. Three years later, the femur remained at i...

متن کامل

Corrosion of cemented titanium femoral stems.

Cemented titanium stems in hip arthroplasty are associated with proximal cement-stem ebonding and early failure. This was well publicised with the 3M Capital hip. However, corrosion in this setting has been reported with only one stem design and is less widely accepted. We present a series of 12 cemented titanium Furlong Straight Stems which required revision at a mean of 78 months for thigh pa...

متن کامل

Cemented Distal Femoral Endoprostheses for Musculoskeletal Tumor: Improved Survival of Modular versus Custom Implants

BACKGROUND Advocates of newer implant designs cite high rates of aseptic loosening and failure as reasons to abandon traditional cemented endoprosthetic reconstruction of the distal femur. QUESTIONS/PURPOSES We asked whether newer, modular distal femoral components had improved survivorship compared with older, custom-casted designs. PATIENTS AND METHODS We retrospectively reviewed 254 pati...

متن کامل

Complications With Long Cemented Stems in Proximal Femoral Replacement.

This study attempted to determine whether patients undergoing cemented long-stem proximal femoral replacement had: (1) an increased short-term mortality rate; (2) greater intraoperative hemodynamic instability; (3) a greater need for resuscitation; and (4) a decreased risk of periprosthetic fracture. The current study reviewed intraoperative and short-term events related to clinical outcomes in...

متن کامل

Loosening of matt and polished cemented femoral stems.

We have compared prospectively the incidence of loosening of 20 femoral stems with a matt surface with that of 20 polished stems of an otherwise identical tapered, non-modular design of Exeter hip replacement. The stems were inserted using the same technique at operation and radiographs showed no difference in the adequacy of the cement mantle or of fixation. All the patients were reviewed regu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Orthopaedics

سال: 2006

ISSN: 0341-2695,1432-5195

DOI: 10.1007/s00264-006-0186-8