Dual-Energy Computed Tomography Proton-Dose Calculation with Scripting and Modified Hounsfield Units

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using Hounsfield Units to Assess Osteoporotic Status on Wrist Computed Tomography Scans: Comparison With Dual Energy X-Ray Absorptiometry.

PURPOSE Rates of evaluation and treatment for osteoporosis following distal radius fragility fractures remain low. As a subset of patients with these fractures undergo diagnostic computed tomography (CT) scan of the wrist, utilizing bone mineral density (BMD) measurements available with this imaging can be used to detect osteopenia or osteoporosis. This information may consequently prompt inter...

متن کامل

Comparison of Tissue Density in Hounsfield Units in Computed Tomography and Cone Beam Computed Tomography

OBJECTIVES Bone quality and quantity assessment is one of the most important steps in implant treatment planning. Different methods such as computed tomography (CT) and recently suggested cone beam computed tomography (CBCT) with lower radiation dose and less time and cost are used for bone density assessment. This in vitro study aimed to compare the tissue density values in Hounsfield units (H...

متن کامل

comparison of tissue density in hounsfield units in computed tomography and cone beam computed tomography

objectives: bone quality and quantity assessment is one of the most important steps in implant treatment planning. different methods such as computed tomography (ct) and recently suggested cone beam computed tomography (cbct) with lower radiation dose and less time and cost are used for bone density assessment. this in vitro study aimed to compare the tissue density values in hounsfield units (...

متن کامل

Evaluation of Effect of Different Computed Tomography Scanning Protocols on Hounsfield Unit and Its Impact on Dose Calculation by Treatment Planning System

Introduction: In radiotherapy treatment planning system (TPS), basic input is the data from computed tomography (CT) scan, which takes into account the effect of inhomogeneities in dose calculations. Measurement of CT numbers may be affected by scanner-specific parameters. Therefore, it is important to verify the effect of different CT scanning protocols on Hounsfield unit (HU) and its impact o...

متن کامل

Computed tomography using proton energy loss.

An experiment has been performed to demonstrate the feasibility of proton computed tomography. The proton energy loss was used to measure the projections of the relative stopping power of the phantom. High quality reconstructions were obtained from scans of 19cm and 30cm diameter performance phantoms. Comparison with reconstructions from an EM1 CT-5005 x-ray scanner showed the proton technique ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Particle Therapy

سال: 2021

ISSN: 2331-5180

DOI: 10.14338/ijpt-20-00075.1