Dual Antegrade Intramedullary Headless Screw Fixation for Treatment of Unstable Proximal Phalanx Fractures
نویسندگان
چکیده
منابع مشابه
Minimally invasive surgical treatment for unstable fractures of the proximal phalanx: intramedullary screw☆
OBJECTIVE To analyze the clinical-functional parameters and quality of life of patients undergoing minimally invasive surgical treatment for extra-articular fractures of the proximal phalanx, using an intramedullary screw (Acutrak(®)). METHODS Between January 2011 and September 2014, a prospective study was conducted on 41 patients (48 fingers) with unstable extra-articular fractures of the p...
متن کاملIntramedullary screw fixation of proximal fifth metatarsal fractures in athletes
OBJECTIVE The purpose of this study was to review the short- and long-term clinical and radiological results of intramedullary compression screw fixation of proximal fifth metatarsal fractures in athletes. METHODS Eleven male and six female active patients with fifth metatarsal zone II and zone III fractures fixed with a 4.5-mm cannulated compression screw were evaluated by chart review, revi...
متن کاملClinical outcomes of limited-open retrograde intramedullary headless screw fixation of metacarpal fractures.
PURPOSE To evaluate clinical and radiographic outcomes in patients treated with limited-open retrograde intramedullary headless compression screw (IMHS) fixation for metacarpal neck and shaft fractures. METHODS Retrospective review of prospectively collected data on a consecutive series of 39 patients (34 men; 5 women), mean age 28 years (range, 16-66 y) treated with IMHS fixation for acute d...
متن کاملBiomechanical comparison of headless antegrade screw versus retrograde cortical screw for coronoid fracture fixation.
OBJECTIVE Posterior-to-anterior directed screws are stronger than anterior-to-posterior directed screws for coronoid fracture fixation. Anterior approaches that facilitate direct reduction and fixation of coronoid fractures have been described. The present study was based on the hypothesis that anterior-to-posterior headless screw (Acutrak Mini® 3.5 mm × 26 mm, Acumed, Hillsboro, Oregon, USA) f...
متن کاملIntramedullary fixation of proximal tibial fractures
is challenging owing to the relatively high chance of displacement during nail insertion. The stability of the proximal fixation is inferior because of the wider diameter of the intramedullary canal in the metaphysis. This has led to the use of Poller screws for additional blocking during intramedullary fixation of proximal or distal tibial fractures.1 The effects of Poller screw is two-fold. F...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: HAND
سال: 2018
ISSN: 1558-9447,1558-9455
DOI: 10.1177/1558944717750919