Dose Verification with diode versus TLD as in-vivo dosimeters for external radiotherapy
نویسندگان
چکیده
منابع مشابه
In vivo dosimetry of intraoral stent using TLD during external photon beam radiotherapy of oral cavity
Introduction: Individual oral stent is a mouth-opening device that used in head and neck cancer radiotherapy with the intention of decreasing radiation dose to health tissues. The aim of this study was to check the dose delivered to both the hard palate and tongue when patient uses the stent during radiotherapy of tongue carcinoma. Methods and materials<stron...
متن کاملIn vivo dosimetry with thermoluminescent dosimeters in external photon beam radiotherapy.
The ultimate check of the actual dose delivered to a patient in radiotherapy can only be achieved by using in vivo dosimetry. This work reports a pilot study to test the applicability of a thermoluminescent dosimetric system for performing in vivo entrance dose measurements in external photon beam radiotherapy. The measurements demonstrated the value of thermoluminescent dosimetry as a treatmen...
متن کاملCVD diamond detectors as dosimeters for radiotherapy
The use of diamonds detectors in radiotherapy and its potential advantages over silicon diodes and ionisation chambers is reviewed. Preliminary results on the performance of CVD diamond detectors in an X-ray beam will be presented. While the devices are sufficiently sensitive, applications as dosimeters are at present limited by time dependent effects. Prospects for further work are described. ...
متن کاملVerification of the Accuracy of the Delivered Dose in Brain Tumors by in Vivo Dosimetry Using Diode Detectors
Introduction: During radiotherapy, high accuracy in the dose delivery is required because there is a strong relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. In many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. In general, the uncertainty in the dose delivered should fall within ± 5% of the...
متن کاملTLD as a tool for remote verification of output for radiotherapy beams : 25 years of experience
The University of Texas M.D. Anderson Cancer Center (UTMDACC) has extensive experience with thermoluminescent dosimetry (TLD) as a quality assurance tool for output and energy monitoring of radiation therapy beams. Over the past 25 years the TLD results of the monitored institutions, commissioning data for TLD readers, the characterization data of lithium fluoride TLD-100 powder and the records...