Distal Radius Volar Rim Fracture Fixation Using DePuy-Synthes Volar Rim Plate

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distal radius volar rim plate: Technical and radiographic considerations

AIM To determine technical considerations and radiographic outcomes of the Synthes volar rim distal radius plate to treat complex intra-articular fractures. METHODS This review highlights technical considerations learnt using this implant since it was introduced in a major trauma unit in November 2011, including anatomical reduction and whether this was maintained radiographically. RESULTS ...

متن کامل

Volar plate fixation of distal radius fractures.

Volar fixed angle fixation may be considered as the beginning of a new era in restoring wrist function to patients with dorsally displaced distal radius fractures even in the face of comminuted or osteopenic bone. A thorough understanding of the anatomy of the wrist is a prerequisite when volarly approaching dorsally displaced distal radius fractures. The demonstration of the device theoretical...

متن کامل

Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

We describe a 59-year-old man who had nonunion of a right distal radius fracture after volar locking plate fixation. He underwent open reduction and internal fixation with a volar locking plate system for a dorsally displaced, unstable distal radius fracture at a previous hospital 5 months ago. Radiographs of the injured wrist showed nonunion of the distal radius with 1.5-mm ulnar minus varianc...

متن کامل

Sternum Fracture Fixation With Volar Radius Plate: A Case Report

Sternum fractures which is a condition seen by 3-8% after blunt thoracic trauma is a situation faced frequently, especially depending on seatbelt usage in traffic accidents. Stabilization is recommended to prevent complications that have high mortality rate like flail chest and cardiovascular injury in sternum fractures. Various materials have been used as a sternal fixation method until now. I...

متن کامل

Meta-analysis for dorsally displaced distal radius fracture fixation: volar locking plate versus percutaneous Kirschner wires

BACKGROUND Dorsally displaced distal radius fractures (DDDRF) are frequent injuries in clinical practice. Traditional percutaneous Kirschner wires (K-wire) and open reduction with volar locking plate (VLP) are the two most common surgical fixation techniques used to manage DDDRF. However, there is no current consensual evidence to guide the selection of one technique over the other. Therefore, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Wrist Surgery

سال: 2016

ISSN: 2163-3916,2163-3924

DOI: 10.1055/s-0035-1570740