Direct Potentiometric Method for Human Stress Determination
نویسندگان
چکیده
منابع مشابه
Direct Potentiometric Method for Human Stress Determination
Stress was firstly defined in 19351, as a reaction of humans to external stimuli. In the modern way of life and every day actions, the term stress is very common and has a significant influence on human reactions, health, work ability and mood. There is also a direct connection between stress and depression in humans2. Apart from adults, recent studies show that preschool children are also unde...
متن کاملDirect potentiometric determination of sodium ion in blood. I. Potentiometric response in simple sodium chloride solutions.
We measured the emf of NaCl solutions (120-160 mmol/L) with a home-built cell in steady-state and with some commercial direct potentiometric analyzers about 20 s after the sample is introduced into the instrument. We compared the results with the theoretical sodium ion activity calculated according to different thermodynamic theories. The slope of the calibration graph was calculated with and w...
متن کاملDetermination of percent hemoglobin A1c using a potentiometric method.
We report a potentiometric method for measuring the hemoglobin A1c (HbA1c, glycated hemoglobin) concentration, hemoglobin (Hb) concentration, and percent HbA1c (%HbA1c) in human blood hemolysate. The %HbA1c is important for diagnosis and management of diabetes mellitus. Alizarin red s (ARS) is used as a redox indicator. Phenylboronic acid (PBA) binds to both ARS and HbA1c via diol-boronic acid ...
متن کاملPolymeric Membrane Sensor for Potentiometric Determination of Tin(II) Ions
Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...
متن کاملBiosensor for direct determination of organophosphate nerve agents. 1. Potentiometric enzyme electrode.
A potentiometric enzyme electrode for the direct measurement of organophosphate (OP) nerve agents was developed. The basic element of this enzyme electrode was a pH electrode modified with an immobilized organophosphorus hydrolase (OPH) layer formed by cross-linking OPH with bovine serum albumin (BSA) and glutaradehyde. OPH catalyses the hydrolysis of organophosphorus pesticides to release prot...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Chemical and Biochemical Engineering Quarterly
سال: 2015
ISSN: 0352-9568,1846-5153
DOI: 10.15255/cabeq.2015.2175